MODULE LEVEL
Ultralight SV1
101.670
SERVICE MANUAL
Proxima ASA
CONFIDENTIAL
7
P
ROBLEM
P
ROBABLE
C
AUSE
R
EMEDY
Fuse breaks instantly
Too much current to the unit
1. Wrong fuse value inserted on the
mains filter
(4)
(at F1)
2. DC power polarity to lamp power
supply inverted at the safety
switch
3. Defective lamp power supply
(6)
4. Defective mains filter
(4)
1. Replace fuse with correct value
(Schurter Type: SP 2.5A Fast 250 VAC)
2. Check DC power connection on safety
switch
3. Replace defective lamp power supply
4. Replace mains filter
Distorted noise from
speakers
Speaker(s)
defective (blown)
Replace housing complete with speakers
Unit shuts off while
being used
Possible overheating
1. Defective main fan(s)
(3)
2. Dirty dustfilter
3. Defective lamp (too much heat
dissipation)
4. Defective 100
°
Celcius Bi-metal
thermo switch
5. Defective main PCB controller
6. Lamp power supply
(6)
(ballast
unit) defective
1. Replace defective main fan/fanhouse
complete or remove obstructing object
2. Clean/replace dustfilter
3. Replace defective lamp
4. Replace fanhouse with fans and thermo
switch
5. Replace defective main PCB controller
and engine
6. Replace defective lamp power supply
Image is flickering or
appears to be unstable
in light intensity
Lamp light is flickering
1. Defective lamp
2. Dirty dustfilter
3. Defective lamp power supply
(6)
4. Defective Polysilicone engine
1. Replace defective lamp
2. Clean/replace dirty dustfilter (overheating
of lamp)
3. Replace defective lamp power supply
4. Replace defective Polysilicone engine
and main PCB controller
Colours break up
1. Bad connection between engine
and main PCB controller
2. User settings not allowed
1. Secure/fix flex cable connection
(See “Work Procedures” in section 7.1.2)
2. Execute Factory reset
White vertical line
appears far right in
picture
Synchronization error
Perform RESET on remote control or
projector panel