MODULE LEVEL
Ultralight SV1
101.670
SERVICE MANUAL
Proxima ASA
CONFIDENTIAL
8
7.1
WORK PROCEDURES
The numbers in brackets ( ) refer to the exploded drawing of the module level elements. An estimate of the
time required for the replacement is also given as a guide for service charges.
7.1.1 GENERAL PROCEDURES
TASK
PROCEDURE
TIME REQ.
GENERAL
Opening the unit
•
Unscrew the 8 pcs cabinet screws, 7 located on the sides of
the projector and 1 at the rear.
•
Remove the zoom and focus rings as described in section
7.1.2.
•
Carefully lift the housing top off the unit and disconnect the
speaker connectors at the front of the main PCB.
5 min.
Reassembling the unit
•
This is assumed to be the necessary stages of any of the
procedures below performed in the reverse order, and finally
the reverse of the “Opening the unit” procedure above.
•
No further instructions will be given unless they differ from
this.
5 min.
Always remember to make a note of the cable connections when performing service, as this
will be of great help when reassembling the product.
All references are seen from the front of the projector.