The Read/Write SNMP Community parameter specifies the a community
supported by the RangeLAN2 Access Point. Actions permitted by this commu-
nity are “read-write” (GET, GET-NEXT, and SET).
The Read/Write SNMP Manager IP Address specifies the IP address of the
SNMP manager which is permitted to use the Read/Write SNMP Community.
An address of 0.0.0.0 indicates any manager may use the community.
The SNMP Trap Community parameter specifies the community that will be
used by the RangeLAN2 752x Access Point when generating TRAP PDUs to
remote managers.
The Trap Target Address specifies the IP address of the device to which
generated TRAP PDUs will be sent. A value of 0.0.0.0 disables trap genera-
tion.
Authentication Traps are sent to the Trap Target Address whenever anyone
attempts to SNMP manage the RangeLAN2 Access Point with an invalid
community or from an invalid community. You may enable or disable the
sending of these traps.
SNMP Supported Traps
The following traps are supported by the RangeLAN2 752x Access Point and
are sent to the SNMP manager defined by the Trap Target Address when they
occur.
MIB II Traps
Cold Start - Sent when the RangeLAN2 752x Access Point powers on or
reboots.
Link Up - Sent by each interface at start-up or after coming back up.
Link Down - Sent when the RangeLAN2 752x Access Point software cannot
initialize or communicate with either interface.
Содержание RANGELAN2 7510
Страница 1: ...RANGELAN2 Access Point Models 7510 and 752x User s Guide 2...
Страница 7: ...vi...
Страница 12: ...5 Figure 1 RangeLAN2 Access Point components...
Страница 13: ...6...
Страница 18: ...11 Figure 4 Cubicle Mount...
Страница 19: ...12 10BASET 10BASE2 Figure 5 Outdoor Enclosure...
Страница 27: ...20...
Страница 51: ...44...
Страница 60: ...53...
Страница 69: ...62 Figure 10 Broadcast Site Survey...
Страница 71: ...64 Figure 11 Directed Site Survey...
Страница 73: ...66 Figure 12 Master Search Tool...