13
12
Specifications
Specifications
Version 1.0
| 13 |
| 12 |
Version 1.0
Battery Indicator light
Green light one:
Winding the rope out
Green light two:
Winding the rope out
Red light:
Winding the rope out
Operation Instructions
1.
Press the power switch (“ON”) of pulling tool, the display light is on. Press the direction
switch “ “, “the green light one” light up, pulling tool is releasing the cable. Press the direction
switch “ “ “the green light one” go out and “The green light two” light up. Pulling tool is in the
winding mode.
2.
Overload and overheating display
1. When the load reaches 90% of the maximum load, the red light lights up and flashes.
2. When the load reaches the maximum load, the “red light” light up, the product stop work-
ing and enter the protection mode.
3. When the battery temperature reaches the setting maximum operating temperature, the
product will stop working and then enter the protection mode.
4. When the electric current is too big, the fuse will break, the “red light” light up, and the
product stop working, please contact the costumer service for repair.
1. The battery indicator light has three colors.
2. When the indicator light is green, battery power is enough, and pulling tool can be used
normally.
3. When the indicator light is yellow, we recommend you charge it before use.
4. When the indicator is red, the battery power is running out. Please charge as soon as
possible.
3.
Battery power display
4.
Limit switch
During normal operation, the stopping switch is turned ON. When the stopping pate reached the
upper limit switch, the operating signal will be ignored. Stop winding cable, when “red light” light
up, reverse the operation direction.
Battery Power Display
Unwinding
Winding
Malfunction or protection
T1000 Display Screen
1.
Display of battery power: five greeds are green. When the battery displays only one grid,
please charge it soon.
2.
Pulling out cable and winding back cable status indicator are displayed in green
3.
When the red cope appears, please solve the problem according to the following table
ERROR CODE
PROBLEMS
SOLUTION
SIGN !
The load reaches 80%
Of the setting load
Remind the user of the weight
CODE 1
Pulling tool stops
working
The load reaches the setting protection load; you
need to reduce the weight
CODE 2
The motor temperature reaches the maximum
temperature; stop using pulling tool and let it
cool to room temperature before using it again
CODE 3
Maximum current reached, fuse brakes; Please
contact costumer service
CODE 4
Stopping limit reached; stop winding cable
4.
When the battery temperature reaches the set temperature. the product stops working and
enters the protection state.
Sometimes, the product will stop working because it has entered protection
mode. At this point, please refer to the error code to reset the product.