Fibre to SAS/SATA RAID Subsystem
16
User Manual
RAID Management
The subsystem can implement several different levels of RAID technology. RAID levels
supported by the subsystem are shown below.
RAID Level
Description
Min. Drives
0
Block striping is provide, which yields higher
performance than with individual drives. There is
no redundancy.
1
1
Drives are paired and mirrored. All data is 100%
duplicated on an equivalent drive. Fully
redundant.
2
3
Data is striped across several physical drives.
Parity protection is used for data redundancy.
3
5
Data is striped across several physical drives.
Parity protection is used for data redundancy.
3
6
Data is striped across several physical drives.
Parity protection is used for data redundancy.
Requires N+2 drives to implement because of
two-dimensional parity scheme.
4
10
Combination of RAID levels 1 and 0. This level
provides striping and redundancy through
mirroring. RAID 10 requires the use of an even
number of disk drives to achieve data protection,
while RAID 1E (Enhanced Mirroring) uses an odd
number of drives.
4 (3)
30
Combination of RAID levels 0 and 3. This level is
best implemented on two RAID 3 disk arrays
with data striped across both disk arrays.
6
50
RAID 50 provides the features of both RAID 0
and RAID 5. RAID 50 includes both parity and
disk striping across multiple drives. RAID 50 is
best implemented on two RAID 5 disk arrays
with data striped across both disk arrays.
6
60
RAID 60 combines both RAID 6 and RAID 0
features. Data is striped across disks as in RAID
0, and it uses double distributed parity as in
RAID 6. RAID 60 provides data reliability, good
overall performance and supports larger volume
sizes.
RAID 60 also provides very high reliability
because data is still available even if multiple disk
drives fail (two in each disk array).
8
Содержание EP-4423
Страница 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 0...
Страница 67: ...Fibre to SAS SATA RAID Subsystem User Manual 67...
Страница 68: ...Fibre to SAS SATA RAID Subsystem 68 User Manual...
Страница 69: ...Fibre to SAS SATA RAID Subsystem User Manual 69...
Страница 70: ...Fibre to SAS SATA RAID Subsystem 70 User Manual...
Страница 71: ...Fibre to SAS SATA RAID Subsystem User Manual 71...
Страница 80: ...Fibre to SAS SATA RAID Subsystem 80 User Manual NOTE Cannot expand Raid Set when contains Raid30 50 60 volume...
Страница 133: ...Fibre to SAS SATA RAID Subsystem User Manual 133 12 Select Yes again to confirm The RAID controller will restart...
Страница 154: ...Fibre to SAS SATA RAID Subsystem 154 User Manual 10 Carefully push the thumbscrew handle until the lock is engaged...
Страница 158: ...Fibre to SAS SATA RAID Subsystem 158 User Manual 6 Replace the front panel 7 Reconnect the cable to the front panel...