![Proware EP-4423 Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/proware/ep-4423/ep-4423_user-manual_1620819106.webp)
Fibre to SAS/SATA RAID Subsystem
106
User Manual
5.5.2 HDD Power Management
MAID (
M
assive
A
rray of
I
dle
D
isks) is a storage technology that employs a large group
of disk drives in which only those drives in active use are spinning at any given time.
This reduces power consumption
and prolongs the lives of the drives.
MAID is designed for Write Once, Read Occasionally (WORO) applications such as Data
Backup, Document, Mail server, and so on.
MAID technology focuses on "Green Storage Concept" to save power consumption and
enhance disk drives effective usage, i.e., "disk drives are spun down when there is no
activity or I/O on the drives".
In the RAID subsystem, MAID is implemented in the
HDD Power Management
menu.
Using the
Advanced Power Management (APM)
function of disk drives, HDD Power
Management has three options (MAID Levels): (Level 1) Place idle drives in Lower Power
Mode, where the drives’ heads are unloaded; (Level 2) Place idle drives in Low RPM
Mode, where drives’ heads are unloaded and slows down to around 4000 RPM; and
(Level 3) Spin down idle drives, where drives stops spinning and goes into sleep mode.
Stagger Power On Control:
This option allows the RAID subsystem’s power supply to power up in succession
each HDD in the RAID subsystem. In the past, all the HDDs on the RAID subsystem
are powered up altogether at the same time. This function allows the power
transfer time (lag time) from the last HDD to the next one be set within the range of
0.4 to 6.0 seconds. Default is 0.7 seconds.
Содержание EP-4423
Страница 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 0...
Страница 67: ...Fibre to SAS SATA RAID Subsystem User Manual 67...
Страница 68: ...Fibre to SAS SATA RAID Subsystem 68 User Manual...
Страница 69: ...Fibre to SAS SATA RAID Subsystem User Manual 69...
Страница 70: ...Fibre to SAS SATA RAID Subsystem 70 User Manual...
Страница 71: ...Fibre to SAS SATA RAID Subsystem User Manual 71...
Страница 80: ...Fibre to SAS SATA RAID Subsystem 80 User Manual NOTE Cannot expand Raid Set when contains Raid30 50 60 volume...
Страница 133: ...Fibre to SAS SATA RAID Subsystem User Manual 133 12 Select Yes again to confirm The RAID controller will restart...
Страница 154: ...Fibre to SAS SATA RAID Subsystem 154 User Manual 10 Carefully push the thumbscrew handle until the lock is engaged...
Страница 158: ...Fibre to SAS SATA RAID Subsystem 158 User Manual 6 Replace the front panel 7 Reconnect the cable to the front panel...