iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
81
5.
Repeat steps 1 to 4 to create another VD.
Two VDs, “VD-R5-1” and “VD-R5-2”, were created from RG “RG-R5”. The size of “VD-
R5-1” is 50GB, and the size of “VD-R5-2” is 64GB. There is no LUN attached.
Step 3:
Attach LUN to VD.
There are 2 methods to attach LUN to VD.
1.
In
“/ Volume configuration / Virtual disk”
, move the mouse pointer to the
gray button next to the VD number; click “Attach LUN”.
2.
In
“/ Volume configuration / Logical unit”
, click “
Attach
”.
The steps are as follows:
1.
Select a VD.
2.
Input
“Host”
name, which is a FC node name for access control, or fill-in
wildcard
“*”,
which means every host can access to this volume. Choose LUN
and permission, and then click “
OK
”.
3.
Done.
VD-R5-1 is attached to LUN 0. VD-R5-2 is attached LUN 1.
NOTE: The matching rules of access control are from top to bottom
in sequence.
Содержание EP-3164D-GAS3
Страница 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Страница 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Страница 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Страница 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Страница 147: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 147 3 Click Done 4 It can connect to an iSCSI disk now ...
Страница 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Страница 151: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 151 13 Click Discover Portal 14 Input IP address of controller2 ...
Страница 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...