iSCSI GbE to SAS/SATA II RAID Subsystem
User Manual
25
NOTE: Each PSFM has one Power Supply and two Fans. The PSFM 1
has Power#1, Fan#1 and Fan#2. The PSFM 2 has Power#2, Fan#3
and Fan#4. When the Power Supply of a PSFM fails, the PSFM need
not be removed from the slot if replacement is not yet available. The
fan will still work and provide necessary airflow inside the enclosure.
NOTE: After replacing the Power Supply Fan Module and turning on
the Power On/Off Switch of the PSFM, the Power Supply will not
power on immediately. The Fans in the PSFM will spin-up until the
RPM becomes stable. When Fan RPM is already stable, the RAID
controller will then power on the Power Supply. This process takes
more or less 30 seconds. This safety measure helps prevent possible
Power Supply overheating when the Fans cannot work.
2.4 Checklist before Starting
Before starting, check or prepare the following items.
;
Check
“Certification list”
in Appendix A to confirm the hardware setting is fully
supported.
;
Read the latest release note before upgrading. Release note accompanies with its
released firmware.
;
A host with a 10GbE NIC or 10GbE iSCSI HBA.
;
CAT 5e, or CAT 6 network cables for management port. FC cable for iSCSI data
ports.
;
Prepare storage system configuration plan.
;
Prepare management port and iSCSI data ports network information. When using
static IP, please prepare static IP addresses, subnet mask, and default gateway.
;
10GbE LAN switches (recommended). Or 10GbE LAN switches with VLAN / LACP /
Trunking (optional).
;
CHAP security information, including CHAP username and secret (optional).
;
Setup the hardware connection before power on servers. Connect console cable,
management port cable, and iSCSI data port cables in advance.
;
In addition, installing an iSNS server is recommended.
;
Power on first, and then power on hosts and iSNS server.
;
Host server is suggested to logon the target twice (both controller 1 and
controller 2), and then MPIO should be setup automatically.
NOTE: iSNS server is recommended for dual controller system.
Содержание EP-3164D-GAS3
Страница 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Страница 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Страница 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Страница 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Страница 147: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 147 3 Click Done 4 It can connect to an iSCSI disk now ...
Страница 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Страница 151: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 151 13 Click Discover Portal 14 Input IP address of controller2 ...
Страница 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...