iSCSI GbE to SAS/SATA II RAID Subsystem
70
User Manual
Standby
options:
“Disabled”
Æ
Disable spindown.
“30 sec / 1 min / 5 min / 30 min”
Æ
Enable hard drive
auto spindown to save power in the period of time.
Read ahead:
“Enabled”
Æ
Enable disk read ahead. (Default)
“Disabled”
Æ
Disable disk read ahead.
Command queuing:
“Enabled”
Æ
Enable disk command queue. (Default)
“Disabled”
Æ
Disable disk command queue.
More
information
Show RAID group detail information.
5.4.3 Virtual Disk
“Virtual disk”
can view the status of each Virtual disk, create, and modify virtual disks.
The following is an example to create a VD.
Step 1:
Click
“Create”
, enter
“Name”
, select RAID group from
“RG name”
, enter
required
“Capacity (GB)/(MB)”, change “Stripe height (KB)”
, change
“Block size
(B)”
, change
“Read/Write”
mode, set virtual disk
“Priority”
, select
“Bg rate”
(Background task priority), and
change
“Readahead”
option if necessary.
“Erase”
option will wipe out old data in VD to prevent that OS recognizes the old partition. There
are three options in “Erase”: None (default), erase first 1GB or full disk. Last, select
“Type”
mode for normal or clone usage. Then click
“OK”
.
Содержание EP-3164D-GAS3
Страница 1: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual Revision 1 1 ...
Страница 85: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 85 ...
Страница 89: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 89 ...
Страница 114: ...iSCSI GbE to SAS SATA II RAID Subsystem 114 User Manual ...
Страница 147: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 147 3 Click Done 4 It can connect to an iSCSI disk now ...
Страница 149: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 149 8 Install 9 Installation succeeded ...
Страница 151: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 151 13 Click Discover Portal 14 Input IP address of controller2 ...
Страница 159: ...iSCSI GbE to SAS SATA II RAID Subsystem User Manual 159 34 Done ...