background image

Home & Business Security Solutions

Содержание AC-930P

Страница 1: ...uman centered Design Quality Assurance Sincere and Faithful Integrated Access Controller Installation Manual LED 1 2 3 4 5 6 7 8 9 0 3000 ProVisual Inc CCTV Security Distributor Integrated Access Cont...

Страница 2: ...onnection Product Connection Installation Manual Installation Manual Product Manual Product Manual Product Maintenance Product Maintenance Home Business Security Solutions Function Debugging Function...

Страница 3: ...should be installed indoor Please consider water proof facility in case outdoor application is needed For detailed information please refer to Product Manual and Wiring Diagram Please make sure insta...

Страница 4: ...D should be higher than 3 5V otherwise exterior reader can not work properly 8 When RS485 is applied voltage between 485 and 485 is around 5 voltages The life of products is related to application env...

Страница 5: ...king Voltage DC9 15V Static Current 120mA Reading Distance 5 10cm Card Type ID card Working Temperature 15 55 Card Capacity 3000pcs Input Interface 1pcs exit button 1pcs door magnet Output Interface 1...

Страница 6: ...st open the lower part of backcover for around 1cm Please note that open too wide may lead to damage to the device 3 Open the back cover and connect the device according to the wiring diagram 4 Fix th...

Страница 7: ...2C 2NO 1NO 1C 1NC GND Valid state door magnet is normal open AC 930P Interface Power Interface AC 930P Interface AC 930P Interface Power Interface Connect with Electric Lock Electric Bolt Iron Core Co...

Страница 8: ...85 485 2C 2NO 1NO 1C 1NC GND GND 12V DAT0 DAT1 SW GND MenC1 BELL BELL RX TX GND 485 485 2C 2NO 1NO 1C 1NC GND 12V GND 262RP 1 2 3 4 5 6 7 8 9 0 GND 12V DAT0 DAT1 SW GND MenC1 BELL BELL RX TX GND 485 4...

Страница 9: ...232 485 Rs232 9 30V 9 30V 485 485 Rs485 12345 DB9 Hole Rs232 Connect with PC or Router AC 930P Interface GND 12V DAT0 DAT1 SW GND MenC1 BELL BELL RX TX GND 485 485 2C 2NO 1NO 1C 1NC GND RS485 GND 12V...

Страница 10: ...ormal state 1C NC is short circuit while C NO is open circuit When present the valid card or press the exit button 1C 1NC turns into open circuit while 1C 1NO is short circuit 1C 1NC 1NO 1C 1NC 1NO No...

Страница 11: ...should be converted to RS232 signal before it can communicate with PC RS485 can connect with multiple devices After ASI 8930 is connected with PC user can detect AC 930P address by detecting serial po...

Страница 12: ...If relay keeps on in open state buzzer keeps buzzing and SW GND is short or lower than the keys maybe damaged 6 MenCi GND is short or lower than 3 5V the door magnet input maybe damaged 7 Voltage of...

Отзывы: