1. If there is no sound when card is presented to the reading area, the reading function maybe
damaged.
2. If there is no sound when press the keys, the keypad maybe damaged
.
3. When add card, if the device exits
program
mode
automatically
,
the
memory
maybe
damaged
.
4. If valid card is read and OK light is on, while relay does not act, the lock control may
malfunction.
5. If relay keeps on in open state
,
buzzer keeps buzzing
,
and SW-GND is short or lower
than
,
the
keys
maybe
damaged
.
6. MenCi-GND is short or lower than 3.5V, the door magnet input maybe damaged
.
7. Voltage of DATA0, DATA1 and GND should be higher than 3.5V, otherwise exterior reader can
not work properly.
8. When RS485 is applied, voltage between 485+ and 485- is around 5 voltages
.
The life of products is related to application environment and application method. Please carefully