Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
3
Configure the Ethernet
interface as required and click the “Exit” button when complete:
Label
Value
Description
DHCP
Enable
Select this option to enable the gauge to automatically acquire its
IP Address, Subnet Mask and Gateway from a DHCP server on
the network.
Disable
Select this option to manually configure the gauge IP Address,
Subnet Mask and Gateway in the fields below:
IP Address
[192.168.1.110]
Enter the IP address assigned to the gauge in dotted decimal
format.
Subnet Mask
[255.255.255.0]
Enter the subnet mask for the network in dotted decimal format.
Gateway
[192.168.1.1]
Enter the gateway for the network in dotted decimal format.
* [ ] indicates factory-default values.
Configuration via input parameters:
This interface may be configured by writing to the following input parameters:
Input parameters
DW
Bit
Comment
Unit
Range/Remark
Default
27
Modbus address
1=1
0~255
1
28
EtherNet protocol
0=Modbus protocol
1=EIP protocol
0
29
DHCP
0=Disabled
1=Enabled
0
30
IP address
x.x.x.x
C0A8016E
(192.168.1.110)
31
32
Subnet mask
x.x.x.x
FFFF0000
(255.255.255.0)
33
34
Gateway
x.x.x.x
C0A80001
(192.168.1.1)
35