Page 112 of 126
Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
DW
Bit
Comment
Unit
Range/Remark
Default
3=Speed hold
4=Reset
14
Logic input 3 polarity
0=Active low
1=Active high
0
15
Must be 0
0=Old format logic inputs
0
12
Logic input(new format;DW12.15=1)
0
Logic input 1 function
0=Direction (count down)
1=Length hold
2=Display hold
3=Speed hold
4=Reset total length
5= End of Reel / Reset batch
length
0
1
2
3
Logic input 1 polarity
0=Active low
1=Active high
0
4
Logic input 2 function
0=Direction (count down)
1=Length hold
2=Display hold
3=Speed hold
4= Reset total length
5=End of Reel / Reset batch
length
1
5
6
7
Logic input 2 polarity
0=Active low
1=Active high
0
8
Logic input 3 function
0=Direction (count down)
1=Length hold
2=Display hold
3=Speed hold
4= Reset total length
5= End of Reel / Reset batch
length
4
9
10
11
Logic input 3 polarity
0=Active low
1=Active high
0
12
Direction setting
(available only when no
logic input for direction)
0=Count up
1=Count down
0
13~14
Not used
15
Must be 1
1=New format logic inputs
13
Laser switch
0=Laser on
1=Laser off
0
14
Length offset
1=0.1m{ft}{yds}{inch}
-3000.0~3000.0m{ft}{yds}
0
15
Pulse output 3 preset
length
1=0.001m{ft}{yds}
1000
16
Logic output function
0~3
LOP1 function
0=Gauge OK
1=Gauge measuring speed
2=Preset length 1 / Batch length
3=Preset length 2 / Batch
number
4=Good reading
5=Object detected
6=Gauge too hot
13=User 1
14=User 2
15=User 3
0
4~7
LOP2 function
2
8~11
LOP3 function
3
13
User I/P 1
0=OPEN
1=CLOSE
14
User I/P 2
0=OPEN
1=CLOSE
15
User I/P 3
0=OPEN
1=CLOSE
17
Pulse output rate
resolution
1=1
3=1000
2=100
1=10
0=1
-1=0.1
-2=0.01
-3=0.001
0
18
Good Reading threshold
1=1%
60%
19
Pulse reset during reset
length
0=Off
1=On
0
20
Profibus address
1=1
0~125
7