Page 111 of 126
Proton Products SL mini and SLR mini Series Speed and Length Gauges Instruction Manual - issue 1s
I
NPUT PARAMETERS
1 DW word = 2 bytes
2013.08.26
DW
Bit
Comment
Unit
Range/Remark
Default
0
System Function
0
Measurement mode
0=Normal mode
1=Batch mode
0
1
Length reset
0=Reset length to zero
1=Accumulate length
1
2
Batch length reset
(available in batch mode
only)
0=Reset length to zero
1=Accumulate length
1
3
Measurement unit
0=metres
1=feet
2=yards
3=other unit(set on PCIS)
0
4
5
Speed signal output
response
0=Averaged
1=Instantaneous
1
6
Pulse output 3 mode
0=Speed
1=Length
0
7
Analogue output source
0=Speed
1=Good Readings
0
8
Length / speed
resolution
0=Length 0.1 / speed 0.01
1=Length 0.0001 / Speed
0.001
1
9
Pulse output 1 mode
0=Normal
1=Quadrature
0
10
Automatic save length
function
0=Invalid
1=Valid
0
11
Object detection switch
0=Off
1=On
0
12
Auto reset when object
detected
0=Off
1=On
0
13
Reset reel number
0=Normal
1=Reset reel number to
zero
0
14~15
Not used
0
1
Preset 1 and 2 decimal
point position
-3~3
0
2
Averaging time
1=5ms
1~1000 (5~5000ms)
200
3
No speed signal hold
time
1=1ms
1~5000 (1ms~5s)
100
4
Batch mode LOP
closure time
1=10ms
1~500 (10ms~5s)
50
5
Preset length 1 or
Preset batch length
1=1/10DW1m{ft}{yds{inch}}
0~65535
1000
6
Preset length 2 or
Preset batch number
1=1/10DW1m{ft}{yds}{inch}
1=1(batch number)
0~65535
2000
7
Pulse output 1 rate
1=1/10DW17pulse/m{ft}{yds}
1~65535
1000
8
Pulse output 2 rate
1=1/10DW17pulse/m{ft}{yds}
1~65535
1000
9
Pulse output 3 rate
1=1/10DW17pulse/m{ft}{yds}
1~65535
1000
10
Analogue output full
scale
1=1m/min{ft/min}
100~9999
3000
11
Minimum speed limit
1=0.1m/min{ft/min}
0~65535 (0~6553.5)
0
12
Logic input (old format: compatible with old SL gauge;DW12.15=0)
0
Logic input 1 function
0=Direction
1=Length hold
2=Display hold
3=Speed hold
1
1
2
Direction setting
(available only when no
logic input for direction)
0=Count up
1=Count down
0
3
Logic input 1 polarity
0=Active low
1=Active high
0
4~7
Not used
0
8
Logic input 2 function
0=Reset input
1=Length hold
0
9
10
Logic input 2 polarity
0=Active low
1=Active high
0
11
Logic input 3 function
0=Direction
1=Length hold
2=Display hold
1
12
13