background image

OPERATIONS MANUAL 

FOR INDUSTRIAL CURTAINS

PROTON HEAT DOOR P1

Safety precautions  

Technical parameters 

Installation

Construction and dimensions

www.protongroup.org

05010416

RU

EN

Water heating

Electric heating

Without heating

ErP

2015

Содержание HD P1-E-7015

Страница 1: ...FOR INDUSTRIAL CURTAINS PROTON HEAT DOOR P1 Safety precautions Technical parameters Installation Construction and dimensions www protongroup org 05010416 RU EN Water heating Electric heating Without...

Страница 2: ...1 Introduction 2 Safety precautions 3 General information 8 Connection of heat medium 3 4 5 4 Dimensions 6 5 Construction 7 6 Technical characteristics 8 10 11 7 Installation 9 Control elements 12 10...

Страница 3: ...The manufacturer preserves the right to alter the construction which doesn t impact its functioning and basic technical parameters The industrial curtain is intended only and exclusively to be instal...

Страница 4: ...ries and death Check correctness of wiring of the system accordance of the heat medium parameters with the parameters indicated on the rating plate as well as leak proof of joints before filling in th...

Страница 5: ...hot water as a heat medium They are very efficient and powerful save money and require low overhead and operating costs Heating curtains with water heating These air curtains apply electric heating el...

Страница 6: ...4 DIMENSIONS 6 Dimensions of industrial curtain PROTON HEAT DOOR P1 Dimensions of a mounting console M HD 560 590 100 2000 560 590 100 1500 462 13 2 160 150 344 13 2 12 50 13 2...

Страница 7: ...ating elements The frame for mounting is made of galvanized steel Joint boxes are equipped with clamping cables Thermal sensors of overheat protection of the finned tubular electric heaters are fasten...

Страница 8: ...dustrial curtain heat power of the industrial curtain air consumption P p Qp P z water temperature at the inlet of the industrial curtain water temperature at the outlet of the industrial curtain wate...

Страница 9: ...ROTON HD P1 F 70 General parameters General parameters 18 0 8000 7 0 68 7 0 54 840 400 50 28 0 68 8 24 0 11000 6 5 70 7 0 54 1260 400 50 37 0 73 2 7 0 230 50 54 840 4 0 68 8500 51 1 7 0 230 50 54 1260...

Страница 10: ...les of 1 5 and 2 m that allows to cover the length of doorway The curtains are to be fixed on mounting consoles Horizontal installation Vertical installation up to 7 m up to 14 m up to 7 m up to 9 m P...

Страница 11: ...the following conditions The air curtain has to be completed with intercepting cocks on the inlet and outlet pipes 1 It is recommended to install a coarse filter on the inlet pipe and air outtake on t...

Страница 12: ...lar electric heaters motors alarm protection are installed The control board RDE is placed in plastic casing with IP65 protection and has a transparent door with additional gasket for manual control Y...

Страница 13: ...urtain without heating to control board RDU 1 2 Tz 1 X1 2 1 5 2 Indicators to the scheme Notes 1 2 joint box of the curtain control board RDU The section is indicated for cables with cooper cores and...

Страница 14: ...ontacts of a group of electric heaters 10 WIRING CONTROL ELEMENTS 10 2 Wiring of industrial curtain with electric heating to control board RDE PE PE Contacts of groups of the overheat sensors Indicato...

Страница 15: ...5 59 4 75 9 95 7 118 8 145 2 171 6 11 6 15 1 19 8 25 7 36 3 46 2 56 1 72 6 92 4 112 2 132 0 4 4 6 1 7 9 13 2 18 7 29 7 50 6 36 3 22 0 44 0 11 0 19 0 27 0 38 0 46 0 70 0 85 0 115 0 135 0 175 0 215 0 2...

Страница 16: ...s heat output Data is presented as a reference For calculations for actual projects address to specialists kW Water consumption Inside diameter Type 15 kW 23 kW 39 kW 61 kW 96 kW 180 kW 20 mm 25 mm 3...

Страница 17: ...17 FOR NOTES...

Страница 18: ...18 FOR NOTES...

Страница 19: ...19 FOR NOTES...

Страница 20: ...vice proton kiev ua www protongroup org www protongroup org In case of any failures in operation of equipment address the authorized support centers of the Manufacturer For information about support c...

Отзывы: