REFLEX RAIL™ BOARD
SETTINGS AND FUNCTIONS
BOARD SETTINGS AND CONFIGURATION MODE
There are five settings you can alter on the RAIL™ board with
the DIPswitches inside the grip frame (see figure 1):
ABS
Anti Bolt Stick.
Trigger Sensitivity
This setting adjusts the delay
between two trigger pulls.
Dwell
This is the time the solenoid is
activated for.
Rate Of Fire
This setting is for adjusting the
maximum rate of fire.
Firing Mode
This is the firing mode the REFLEX
RAIL™ uses.
There are two DIPswitches mounted on the board of the
REFLEX RAIL™ (See figure 1). The first one is used for the
ABS setting and the second one is used to access a
configuration mode, which changes the other four settings.
Anti Bolt Stick
- When ABS is activated, the dwell is increased after
15 seconds of non-use for the next shot fired. This helps to prevent
bolt-stick, but may result in higher velocity for the first shot.
CONFIGURATION MODE
- The following settings can only be
modified in configuration mode. To activate the configuration
mode, turn your marker off and set DIPswitch 2 to the ON
position. Next, turn your marker on. The LED's cycle through
all colors for one second to indicate that you have entered
the configuration mode.
To cycle through different settings, pull and release the trigger.
Configuration mode has 4 settings that can be changed.
.
TO CHANGE A VALUE OF A SETTING
1. While in the configuration mode, choose the color you wish to change by pulling the trigger to
cycle through different options.
2. When the LED indicates the color you wish to change, pull and hold the trigger until the LED
starts to flash.
3. The LED will flash as many times as the previous setting was and it will then turn off. Now pull
the trigger as many times as you wish the new setting to be – if you do not wish to alter the value
of the setting, you must re-enter the previous setting.
4. When done, the LED will cycle through all the colors again to indicate setting was saved and
turn back to green. You can now change another setting or quit the configuration mode.
5. To exit configuration mode, set DIP 2 to the off position.
REFLEX RAIL™ BOARD
SETTINGS AND FUNCTIONS
W
W
W
.
P
R
O
T
O
P
A
I
N
T
B
A
L
L
.
C
O
M
W
W
W
.
P
R
O
T
O
P
A
I
N
T
B
A
L
L
.
C
O
M
8
9
ABS ON
(DEFAULT)
ABS OFF
NORMAL
MODE
CONFIGURATION
MODE
FIGURE 1
2011-Reflex-RAIL-Manual.qx_2011-Reflex-RAIL-Manual 11/22/10 12:40 PM Page 11