REFLEX RAIL™ BOARD
SETTINGS AND FUNCTIONS
BLUE - Rate Of Fire (ROF)
Values 1 - 45
The ROF setting is used to set the maximum rate of fire of the RAIL™.
The values do not correspond directly to a certain Balls Per Second
(BPS) value. You will need to use the table below to locate your
desired maximum ROF setting.
The factory setting is
20
(
12.5 bps
).
Increasing ROF too high will increase probability of ball breakage.
If this occurs decrease ROF setting.
YELLOW - Firing Mode
Values 1 - 4 (default 1)
This setting changes the firing mode of the REFLEX RAIL™. Default is
semiautomatic. In the semiautomatic mode, one trigger pull shoots
out one paintball. The PSP mode and the Millennium modes follow
the rules of the paintball tournament series.
Value 1
- Semi-automatic Mode
Value 2
- Millennium Mode
Value 3
- PSP Mode
Value 4
- Full auto with first shot safety feature
W
W
W
.
P
R
O
T
O
P
A
I
N
T
B
A
L
L
.
C
O
M
W
W
W
.
P
R
O
T
O
P
A
I
N
T
B
A
L
L
.
C
O
M
10
11
1
9.80
BPS
2
9.90 BPS
3
10.0
BPS
4
10.10 BPS
5
10.20 BPS
6
10.30 BPS
7
10.41 BPS
8
10.52 BPS
9
10.63 BPS
10
10.75 BPS
11
10.86 BPS
12
10.98 BPS
13
1 1 .1 1
BPS
14
11.62
BPS
15
11.76
BPS
16
11.90 BPS
17
12.04 BPS
18
12.19
BPS
19
12.34 BPS
20
12.50 BPS
21
12.65 BPS
22
12.82 BPS
23
12.98 BPS
24
13.15
BPS
25
13.33 BPS
26
13.51
BPS
27
13.69 BPS
28
13.88 BPS
29
14.08 BPS
30
14.28 BPS
31
14.49 BPS
32
14.70 BPS
33
14.92 BPS
34
15.15
BPS
35
15.38 BPS
36
15.62 BPS
37
15.87 BPS
38
16.12
BPS
39
16.39 BPS
40
16.66 BPS
41
20.00BPS
42
20.22 BPS
43
25.0
BPS
44
28.57 BPS
45
33.33 BPS
REFLEX RAIL™ BOARD
SETTINGS AND FUNCTIONS
GREEN - Trigger Sensitivity
Values 1 - 20 (factory default 5)
Trigger sensitivity is the amount of time that the trigger has to be
released before the next trigger pull is allowed. In some situations
with too low of a value, the REFLEX RAIL™ can register more trigger
than what was actually pulled. This can cause the REFLEX RAIL™ to
auto, even in semi-automatic mode. To fix this, adjust the trigger
sensitivity setting higher.
RED - Dwell
Values 1 - 30 (factory default 18)
Dwell is the amount of time that the solenoid will be activated.
Follow these steps for the best way to set your dwell:
• Remove loader and any paintballs from the RAIL™ marker.
• With the dwell set at 10, start increasing the value until the marker
begins to fire.
• When you reach the setting where the marker begins to fire, get
some paint and a loader and go to a chronograph.
• Increase the dwell until you see no increase in the velocity.
This is the optimal dwell setting to be used.
NOTE: You cannot turn your marker off with the power button
when the marker is in configuration mode. You must first set DIP
switch 2 to the OFF position.
2011-Reflex-RAIL-Manual.qx_2011-Reflex-RAIL-Manual 11/22/10 12:40 PM Page 13