P2_PANTHER_user manual_ work basis_EN_03 - 07/11 - Protherm
- 44 -
NEED HELP?
Description
Units
PANTHER 12 KTO
Gas category
II2H3P
Distribution
C12, C32, C42, C52, C82, B22
Ignition
electronic
Power/ fuel
natural gas
propane
Maximum thermal consumption
kW
13,8
Minimum thermal consumption
kW
4,4
Maximum thermal output
kW
12,6
Minimum thermal output
kW
3,5
Ef
fi
ciency
%
91,5
Maximum gas consumption
m
3
/h
1,46
Minimum gas consumption
m
3
/h
0,45
Maximum gas consumption
kg/h
0,91
Minimum gas consumption
kg/h
0,36
NO
x
classi
fi
cation
3
Gas pressure
Inlet pressure
mbar
20
37
Membrane diameter
mm
4,8
-
Maximum pressure in discharge nozzles
mbar
14,5
36
Minimum pressure in discharge nozzles
mbar
1,65
6,2
Discharge nozzle diameter
mm
1,25
0,73
Heating
Maximum working pressure
bar
3
Minimum working pressure
bar
0,5
Recommended operating pressure
bar
1 - 2
Temperature range
°C
38 - 80
Expansion tank
l
7
Maximum pressure in the expansion tank
mbar
3
Hot water
Maximum pressure
bar
-
Minimum pressure
bar
-
Minimum HW
fl
ow
l/min
-