Part 4: Installation and Start-up
Remote
controls
49
Remote controls
Operation-control module BM 8
(Only for controller models with CAN-Bus connection)
Electrical connection: Connector IX; 1-4
The controller permits connection of an operation-control
module BM for each heating circuit via a bus line. The
operation-control module allows various operation-control
functions and monitoring functions for the system values to
be relocated to the main controlled zone – i.e. the living
room. This achieves maximum comfort and convenience.
Please refer to the technical description of the BM for a
precise description of the overall scope of functions.
•
Display of the system parameters
•
Entry of the heating circuit parameters
•
Room temperature control
•
Automatic adaptation of the heat slope
Remote control FBR2
Electrical connection:
Connector I; 1-3 and connector III; 1-3
•
Rotating switch for modifying room temperature setting
Adjusting range: (±5 K)
•
Room control via the integrated room sensor
•
Rotating switch for selecting operating mode
i
Standby/OFF (frost protection only)
q
1
Automatic mode (according to timer program 1 in
controller)
q
2
Automatic mode (according to timer program 2 in
controller)
C
24-hour night operation (reduction temperature)
B
24-hour daytime operation (comfort temperature)
F
Summer mode (heating OFF, hot water only)
!
The heating program switch on the controller must
be set to
q
.
1
2