1. The PULSE rate will be displayed after detected 4 stable pulse signals and it will be
updated by receiving every 2 signals.
2. Each pulse rate signal will be accompanied with one “
♥
” symbol flash.
FUNCTIONS DISPLAY
VALUE
TIME
00:00 ~ 99:59 (COUNT UP)
05:00 ~ 99:00 (COUNT DOWN)
SPEED
0.00 ~ 99.9 KPH (or MPH)
DISTANCE
0.0 ~ 999.9 Km (or Mile)
RPM
0 ~ 999
CALORIE
0.0 ~ 99.9 ~ 100 ~ 999 Kcal
PERFORMANCE VALUE
0 ~ 999
AGE
1 ~ 99
PULSE
40 ~ 240
F. MOTOR PROTECTION :
This is a warning message to users for reminding them if there’s something wrong with
this system.
1. Whenever turn on the power switch, CPU will check if the small motor is at level 1
(Resistance/effort = 1). If not, the monitor will send command to driver motor to level 1.
If there’s no response from the motor, monitor will show “E1” on graphic display.
2. During exercising, if you press
♁
or
\
key to adjust workout level but the motor does
not response and repeated three times. The monitor will display the “E1” and generate
a beep sound. You can press Start/Pause key to stop the beeping.
**In above condition, it’s better to check if all the connections between monitor and
motor are normal and whether the motor is working well or not. Then you can re-start
the monitor. If the monitor still presents “E1” & beeps, it’s better to call service man.
G. LCD CONTRAST CALIBRATION :
1 During PAUSE mode, press & hold ENTER &
♁
keys simultaneously for over 2
seconds to enter LCD CONTRAST CALIBRATION mode.
2 Then you can press
♁
or
\
key to adjust the LCD contrast to be lighter or darker.
3 After completion LCD CONTRAST CALIBRATION, press START/PAUSE KEY to exit.
4 There are 16 different LCD contrast level can be adjustable.