background image

 

1/5

0000356

TM 15 

SAFETY TRIPOD

EN 795/B TS 16415/B 

ed. 

1/22.01.2020

Fig. 1 – General view of device TM15

1. GENERAL DESCRIPTION
Safety tripod TM15 is an anchor point compliant with EN 795/B and document 
TS 16415/B and can be used as a component of fall protection equipment.
Tripod TM15 provides protection for up to 3 users at a time.
Tripod TM15 is composed of powder-coated aluminium head, equipped with 3 
polyamide rollers with bearings (for work guidance in rescue devices CRW200 / 
RUP502-U / RUP503-U / RUP504 / RUP506). The head is fitted with 3 anchor 
points located at its side walls. Each of these points can be used as an anchor 
point for fall protection equipment. One point is designed to be used by 
maximum one user at a time.
The above mentioned rescue devices can be mounted on each of three 
aluminium telescopic legs by means of universal holder UTB (AT017-300). Each 
telescopic leg is terminated with a foot made of zinc-plated steel, equipped 
with rubber pad. Each foot has teeth which penetrate through loose or slippery 
ground (soil, sand, grit, ice, snow). Inner leg is locked in outer leg using 
automatic pin with locking fins which are released by button in pin holder.
Basic parameters of device:
·

Maximum height “under head”: 3.13m

·

Minimum height “under head”: 1.97m

·

Range of diameters above which tripod can be unfolded: 1.1...1.7m.

2. LOAD LIMIT AND STRENGTH

a) GENERAL INFORMATION
Minimum Breaking Strength (MBS): 21kN.
The device can be loaded vertically downwards within a space limited by legs of 
the device.
Maximum load that could be transmitted in service from the device to the 
static construction – 10kN.
If the device is used as a part of a fall arrest system, the user must be equipped 
with an element limiting maximum dynamic forces applied on user while 
arresting a fall to max. 6kN.

b) FOR MATERIAL TRIPODS
installed on the tripod head and/or leg using universal holder UTB (AT017-300):
Working Load Limit (WLL): 1000kg
Safety Factor (SF): 2,1:1.

c) FOR PERSONAL PROTECTIVE EQUIPMENT (PPE) mounted to anchor points 
located on the head:
Maximum 3 users at the same time. Whereas one user is connected to one 
anchor point.
According to the requirements of EN 795/B and document TS 16415/B strength 

of the device is min. 14kN

d) FOR DEVICES FOR PERSONNEL RESCUE
installed on the tripod leg using universal holder UTB (AT017-300):
Working Load Limit (WLL): 200kg
Safety Factor (SF): 10:1.
Work load of rescue device used cannot be greater than 200kg.

Fig. 2 – Permissible directions of loading of anchor point within inner area 
determined by tripod legs

3. TRANSPORT AND WEIGHT
Weight of complete device: 28.7kg.
Personal fall protection equipment must be 
transported in a package (e.g.: bag made of 
moisture-proof textile or foil bag or cases 
made of steel or plastic) to protect it against 
damage or moisture.

4. MAINTENANCE AND STORAGE
Personal protective equipment should be 
cleaned without causing adverse effect on 
the materials used in the manufacture of the 
equipment. For textile materials (webbings, 
ropes) use agents suitable for delicate 
fabrics. Can be washed in hands or in a 
washing machine. Rinse thoroughly. Wash 
textile elements with water only.
- When the equipment becomes wet, either 
from being in use or after cleaning, allow it 
to dry naturally, and keep it away from 
sources of heat. In metallic products 
lubricate slightly some mechanical parts 
(springs, hinges, pawls, etc.) regularly to 
ensure their better operation.
Personal fall protection equipment should 
be stored loosely packed in well-ventilated 
rooms, protected from direct light, UV 
degradation, dust, sharp edges, extreme 
temperatures and aggressive chemical 
substances.

Fig. 3 – Transport dimensions

 READ AND UNDERSTAND INSTRUCTION MANUAL 

BEFORE USING THE EQUIPMENT 

Содержание TM 15

Страница 1: ...r while arresting a fall to max 6kN b FOR MATERIAL TRIPODS installed on the tripod head and or leg using universal holder UTB AT017 300 Working Load Limit WLL 1000kg Safety Factor SF 2 1 1 c FOR PERSONAL PROTECTIVE EQUIPMENT PPE mounted to anchor points located on the head Maximum 3 users at the same time Whereas one user is connected to one anchor point According to the requirements of EN 795 B a...

Страница 2: ...tion of device c Reference number d Number year class of European standard e CE mark and number of notified body which supervises the production of the equipment f Month and year of manufacture g Serial number of device h Attention read instruction manual i Mark of device s manufacturer or distributor j Maximum number of concurrent users Fig 6 Identity label of device TM 15 Fig 7 Location of marki...

Страница 3: ...er The chain should be well tensioned between tripod legs If necessary remove any excess clearance Instead of chain special strip delivered with tripod can be used g Optionally it is possible to install steps AT013 300 allowing for easy access to the device head during installation of work rope Steps are installed by pushing cotter bolt in inner leg adjustment holes h For tripod TM15 it is recomme...

Страница 4: ... proper operation rollers bolts and rivets connectors energy absorber ü In connectors snap hooks load bearing body rivets main pawl locking mechanism functionality At least once a year after each 12 months of use personal fall protection equipment must be withdrawn from use to carry out periodic detailed inspection Periodic inspection may be carried out by a person who is responsible for periodic ...

Страница 5: ... particular attention to risks affecting the protective equipment operation or the user s safety and in particular to kinks and rope movement on sharp edges oscillatory falls electricity influence of extreme temperatures equipment damage negative influence of environmental factors chemical substances and contamination Do not modify repair components of the system or replace them with non original ...