ENGLISH | AS-6030
21
on the RECEIVER and the teach-in process is completed.
After that the LED Status (3) turns to red and green.
8. You can set the current furnace status (hot or cold) by
pressing the Status button (11) on the furnace transmit-
ter (9). However, this is also automatically transmitted
during the next status change.
9. The TRANSMITTERS on the RECEIVER are now taught in
and the AS-6030.3 is ready for use.
TEACHING IN MULTIPLE TRANSMITTERS
1. Press the button (2) on the receiver for 2 seconds. The
LED Status (3) begins to flash red.
2. Place a battery / the batteries in the TRANSMITTER to
be taught in.
3. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing and removing it again or
pressing the Status button. The LED Status (3) stops
flashing on the RECEIVER and the teach-in process is
completed.
4. Repeat steps 1), 2) and 3) for each individual
transmitter.
5. If 2 window transmitters and 2 furnace transmitters are
taught in, no further transmitters can be added.
DELETING individual or all TRANSMITTERS
Deleting individual TRANSMITTERS
1. Press the button (2) on the receiver for 2 seconds. The
LED Status (3) begins to flash red.
2. Activate the TRANSMITTER to be deleted by holding the
magnet once on the housing and removing it again or
pressing the Status button. The LED Status (3) stops
flashing on the RECEIVER and the deletion is completed.
CODING THE EXHAUST AIR CONTROL
Preparation
Connect the sensor cable (K) to the furnace transmitter.
On the back of the furnace transmitter there are two screw
terminals, marked RED and BLACK. Loosen both screws and
slide the red cable lug of the thermos-sensor under the screw
marked RED and the other cable lug under the screw marked
BLACK. Tighten the screws again.
The window transmitter (4) and the furnace transmitter (9)
are not coded at the factory and must be taught in to the
receiver during the initial commissioning.
Please follow the order indicated precisely!
1. Connect the receiver to the power supply.
If the device is functioning properly the LED Status (3)
lights up red for 20 seconds and then goes off.
2. Insert the battery (CR 2477) in the window TRANSMIT-
TER (4). The LED (5) on the transmitter lights up briefly.
3. At the RECEIVER keep the Code button (2) pressed down
for 2 seconds until the LED Status (3) begins to flash red.
4. Activate the window TRANSMITTER by holding the
magnet once on the housing and removing it again.
The LED integrated in the transmitter lights up. At the
RECEIVER the LED Status (3) now lights up red and the
teach-in process is completed.
5. Place the batteries (2x AA) in the FURNACE TRANSMIT-
TER (9). The LEDs on the transmitter (12 and 13) light
up briefly.
6. Press the RECEIVER button (2) again for 2 seconds, the
LED Status (3) begins to flash.
7. Activate the FURANCE TRANSMITTER (9) by pressing
the Status button (11) once. The LEDs integrated in the
transmitter light up. The LED Status (3) lights up green
Содержание AS-6030
Страница 1: ...AS 6030 3 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI GEBRUIKSAANWIJZING V2 ...
Страница 2: ...AS 6030 DEUTSCH 2 EMPFÄNGER 3 1 2 Zuleitung Lüfter ...
Страница 13: ...DEUTSCH AS 6030 13 ...
Страница 14: ...AS 6030 ENGLISH 14 RECEIVER 3 1 2 Connection example 1 Connection example 2 Zuleitung Lüfter ...
Страница 15: ...ENGLISH AS 6030 15 U 4 6 4 6 WINDOW TRANSMITTER U 6c 6b 6a 5 4a ...
Страница 25: ...ENGLISH AS 6030 25 ...
Страница 26: ...AS 6030 FRANÇAIS 26 RÉCEPTEUR 3 1 2 Exemple de raccordement 1 Exemple de raccordement 2 Zuleitung Lüfter ...
Страница 27: ...FRANÇAIS AS 6030 27 U 4 6 4 6 EMETTEUR DE POÊLE U 6c 6b 6a 5 4a ...
Страница 38: ...AS 6030 NEDERLANDS 38 ONTVANGER 3 1 2 Aansluitvoorbeeld 1 Aansluitvoorbeeld 2 Zuleitung Lüfter ...
Страница 39: ...NEDERLANDS AS 6030 39 U 4 6 4 6 RAAM ZENDER U 6c 6b 6a 5 4a ...
Страница 49: ......
Страница 50: ......
Страница 51: ......