PROTECT MultiCard
™
9
Re-trigger blocking is for this input limited to only 5 seconds, following any other fog release.
Input 3 is intended for connection to seismic detectors, glass break, and/or detectors that detect introduction
of gas into the ATM machine .
If it is activated, it will fire a preselected protection shot, to deter anyone from breaking the ATM by brute
force, or by introduction of air/gas mix to be detonated.
There are no limits to the number of such shots possible (besides limits on fluid content).
This input is fixed “normally closed” (activates when NO voltage is applied).
Possible settings are:
Possible settings are:
Re-trigger blocking is for this input limited to only 5 seconds, following any fog release.
The third trigger method is intended for the event that the ATM door is forced open.
In this case a large amount of initial fog may be required to fill the premises, and a series of pulses may be
required to keep the premises filled until security personnel arrives.
The third trigger method is controlled entirely by inputs and settings on the mainboard like in any other fog
protection application without the use of a MultiCard .
Retrigger blocking is for this input limited to 30 seconds, following any fog release.
Please note that
fluid warning level will correspond to the fog settings on the mainboard!
Output 1 is in this mode a dedicated “fog has been activated” output, that will activate (close) when the fog is
released. It will stay activated (closed) until “Disable” on the mainboard has been activated.
This will indicate to staff weather the fog protection system was activated or not.
Note: the “fog” relay output on the mainboard will still indicate when fog is active, but will release once fog
production stops again .
Outputs 2 to 9 signal various fault conditions on separate outputs.
See list above.
Do NOT rely solely on the fault indicating outputs on the MultiCard.
Fault, Fluid and Fog outputs on fog cannon mainboard should still be monitored for activity.
Please note that all trigger
inputs are edge triggered and that re-triggering after a fog release depends on
signals, returning to their normal level (closed) before again being activated (opened).
Fog volume
Dip setting
Dip 7 & 8
0,0
1,0
0,1
1,1
Shot type
5s turbo
10s turbo
20s normal
40s normal
85 m
3
170 m
3
290 m
3
540 m
3
Fog volume
Dip setting
Dip 9 & 10
0,0
1,0
0,1
1,1
Shot type
20s normal
40s normal
60s normal
30s turbo
290 m
3
540 m
3
700 m
3
600 m
3