![Protect MultiCard Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/protect/multicard/multicard_installation-manual_1619835012.webp)
PROTECT MultiCard
™
12
6.4. ATM protection mode on PROTECT 2200i with separated fault outputs
Software requirement, fog cannon: Software version 2.91 or higher.
Software requirement, MultiCard: Software version 1.05 or higher.
Device requirements: This program is specially designed for
PROTECT 2200i ONLY!
Attempts to use this feature on other machines may result in unpredicted behavior.
Dipswitch settings:
1
1
2
1
3
0
4
0
5
0
6
0
7
Fog 2
8
Fog 2
9
Fog 3
10
Fog 3
Terminal “V+” is currently not used, and should be left unconnected.
This program functionality has been specially tailored for protection of ATM machines.
It combines three different trigger methods, with individual fog settings.
Input 2 is intended for connection to detectors that detect attempts to manipulate the ATM shutter .
If it is activated, it will fire a preselected
warning shot to deter anyone from manipulating the shutter
mechanism .
A limit of maximum 3 shots is possible. This will be reset by Disable signal on the mainboard.
A minimum break of 5 minutes (blocking timer) between such “warning activations” is required.
This feature is to limit the amount of Fog Fluid that may be wasted due to this type of manipulation.
This input is fixed “normally closed” (activates when NO voltage is applied).
Inputs functionality:
IN-SS
Activates “Blocking mode” when connected to gnd on mainboard.
IN-2
ATM shutter manipulation (normally closed)
IN-3
Seismic, glass break and/or gas sensor (normally closed)
IN-4
No function
Outputs functionality:
OUT-1
Fog has been activated (will stay closed until Disable is activated on mainboard)
OUT-2
E1_MAINS_VOLTAGE_LOST
OUT-3
E3_FIRE_ALARM_ACTIVE or E16_PANNIC_NOT_RELEASED
OUT-4
E4_BATTERY_VOLTAGE_LOW or E5_BAT_CHARGE_TIMEOUT or E6_BAT_LOADTEST_FAIL
OUT-5
E7_BOARD_TEMP_HIGH or E8_BOARD_TEMP_LOW or E14_BAT_TEST_CIRC_FAIL
OUT-6
E9_TEMP_TERM_HIGH
OUT-7
E10_TEMP_TERM_LOW
OUT-8
E12_PUMP_TIMEOUT
OUT-9
E13_AUX_12V_OVERLOAD