![Proteco myGate PQ81A Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/proteco/mygate-pq81a/mygate-pq81a_instruction-manual_1619761004.webp)
SENS
POWER
2 Q81A_5_2021
24V
ac
230V
ac
F2
J5
JP7
JP8
JP9
1 2 3 4 5 6 7 8 9 10 11
12 13 14 15 16 17
18 19 20
JP1
JP2
JP3
TR2
POWER
230Vac
5A
230Vac
DL1
- +
- +
SENS
POWER
K4
K2
K3
- +
- +
V1
FR1
SET
SET TX
WORK
BREAK
21 22
SW1
SW2
DL2
DL3
START STOP PED
DL4 DL5 DL6 DL7 DL8
FR2
J1
SET
SET TX
WORK
BREAK
2. DESCRIPTION AND MAIN COMPONENTS
J1
= radio module
J5
= input for electrolock or second radio channel jacks
F2
= line fuse 230V 5A
FR1
= self resettable fuse 24V 1,6A
FR2
= self resettable fuse 24V 0,6A
V1
= varistor secondary
K2/K3
= motors relé
K4
= flashing light relé
TR2
= filter
JP1
= GREEN TERMINAL - aerial connection
JP2
= Secondary MOLEX card 24V ac
JP3
= Primary MOLEX card 230V ac
JP4
= BLUE TERMINAL – command devices
JP5
= RED TERMINAL - line and photocells
JP6
= YELLOW TERMINAL – flashing light
JP7
= ORANGE TERMINAL - motor 1 (M1)
JP8
= BLACK TERMINAL - motor 2 (M2)
JP9
= GREEN TERMINAL – line 230V / earth
SENS
= OBSTACLE DETECTION adjuster
POWER
= THRUST adjuster
SW1 - SW2
= FUNCTIONS SELECTION – dip switches mode
PROGRAMMING BUTTONS
WARNING LED
DL1
= PROGRAMMING
DL2
= THRUST MOTOR 1
DL3
= THRUST MOTOR 2
DL4
= START
DL5
= STOP
DL6
= PEDESTRIAN START
DL7
= PHOTOCELL IN CLOSING
DL8
= PHOTOCELL IN OPENING
PROTECO S.r.l.
Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 [email protected] - www.proteco.net