12 Q81A_5_2021
4. DEFAULT SETTINGS
LThe control panel is supplied with a
DEFAULT SETTINGS
: working time and delay are set for a standard 90° opening.
To reload the DEFAULT SETTINGS:
- Press
BREAK
to cut the power OFF and ON
- Turn SENS to the maximum (+) and
POWER
to half position.
5. BROWSING THE MENU
5.1
FUNCTIONS MENU
5.1.1 AUTOMATIC CLOSING
The
AUTOMATIC CLOSING DEFAULT
is set at 3 sec.
To set the AUTOMATIC CLOSING TIME:
- Press
SET
for 3 sec.
DL1
blinks, release
SET
.
- Press
BREAK
and release.
- The blinker and led
DL1
light up, the control panel starts the count down.
- Press B
REAK
again when reached the desired time, the blinker turns off.
The time has been set (automatic closing time max. 120 sec.)
To desactivate the
AUTOMATIC CLOSING
:
- Press
SET
for 3 sec. and release, the led
DL1
blinks.
- Press
BREAK
and hold for 5 sec., the
AUTOMATIC CLOSING
has been desactivated
5.1.2 8K2 RESISTIVE SAFETY EDGE INPUT
(just in opening)
To activate the
8K2
input as safety in opening press
SET + SET TX
while turning the control panel on.
SET
Use
SET
:
- To programm the control panel (section
8.1.
AUTOMATIC MODE –
8.2.
SEQUENTIAL MODE).
- To activate or desactivate the automatic closing (section
5.1.1
)
SET TX
Use
SET TX
:
- To store or to delete a radio code.
WORK
Use
WORK
:
- As START command
- For SEQUENTIAL PROGRAMMING
TASTO
BREAK
Use
BREAK
:
- To activate and set the AUTOMATIC CLOSING TIME (section
5.1.1
)