10
HOW TO PROGRAM THE INSTALLER’S LEVEL CONTINUED FROM PAGE 9
3. SALT LEVEL
The control will display:
• Press the UP or DOWN ARROW to select Low, Medium, or High. Medium is a good setting for most
circumstances. For small families and low hardness, Low will provide greater salt efficiency. For large
families and high hardness, High will provide the most capacity.
Press the SCOLL BUTTON to advance to the next setting.
4. RESERVE CAPACITY
The control will display:
• To adjust the reserve, press the SCROLL BUTTON. Use the UP OR DOWN ARROW to set the reserve
capacity in increments of 10 gallons, up to 70% capacity of the bed.
• To calculate the reserve capacity, take the number of people in the home and multiply it by 70 gallons
per day. The reserve capacity will equal one day of water use.
Example: 3 people X 70 gallons per day = 210 gallons (suggested reserve capacity)
• If you prefer, you can select a Variable Reserve. While at the Reserve screen when “Fxd” is flashing,
press the UP OR DOWN ARROW. The control will display:
• The reserve capacity will be calculated automatically, based on the registered daily water consump-
tion. The initial setting is 25% of the capacity, which will adjust over time to accurately reflect daily
water use.
Press the SCROLL BUTTON to advance to the next setting.
5. TIME OF REGENERATION
The control will display:
• Press the UP or DOWN ARROW to adjust the time of regeneration.
Regeneration should be set for a time when water use is minimal. 2:00 AM is good for most house-
holds.
Note: The system diverts hard water to the home during regeneration. If any water is drawn
during regeneration, some hard water will enter the plumbing system and possibly the hot water
tank. Keep in mind that the regeneration cycle can last up to two hours after the starting time.
Press the SCROLL BUTTON to advance to the next setting.
6. DAYS OVERRIDE
The control will display:
• Press the UP or DOWN ARROW to set the number of days between regenerations. The setting range
is OFF to 30 days.
Note: In most situations with a meter equipped valve, override can remain “OFF”. Set a number if
days if you wish to have the filter bed refreshed periodically regardless of water use.
Press the SCROLL BUTTON to advance to the next setting.
Salt Level: Med
Rsrv: 200 GL Fxd
Rsrv: Variable
Regen @ 2:00 am
Override: OFF
Содержание SIZE 1.0
Страница 15: ...15 VALVE EXPLODED VIEW ...