ProStart CT-3200 Скачать руководство пользователя страница 15

CT-3200 

Installation Guide  

P. 15

 

 

 

When all of the wires have been connected, solder the connections. When the solder has 
cooled, the connections are then individually taped up, to isolate them.  

 

 

Return to the engine bay and route the start module wires to their corresponding connections.  

 

 

Solder the engine compartment wire once the connections are made. When the solder has 
cooled, the connections are then individually taped up, to isolate them.  

 

 

Use your DMM to verify your ground location is good, before Grounding the module.  

 

 

The last step before programming is to power the module up. Replace the power fuses on the 
power wire fuse holders. The module will flash the Park lights twice confirming the powering up. 

 

 

If you are installing an Alarm / Starter combo module: The siren will be sounding at this point. 
Place the module into Valet mode to silence the siren. Take the module out of valet mode to 
continue the programming. ( 

note:

 the module default programming is passive arming, after 

exiting valet mode, the alarm will start the count down for passive arming. You have 30 sec. to 
begin the Remote control programming procedure, before the module re-arms) 

 
- Program the Remote control 
- Program the Tach Signal 
- Change the programming of the options, if necessary  
- Test the module's operations  
- If all of the testing is successful the install is complete, and the vehicle can be put back together. 

A basic introduction to the Relay:  

What is a relay? 

A device that responds to a small current or voltage change by activating switches or other devices 
in an electric circuit. An electromagnetic switch, remote controlled switch, a switching device.  
 

Why are Relays used? 

Relays can have several purposes in remote car starter installations. They are used mainly for 
isolation, inversion, interruption, strengthening current, and for 

powering multiple wires from one 

source SAFELY

.  

 

How does it work? 

The basic relay consists of a coil and a set of contacts. The most common relay mechanism is 
electromagnetic. When voltage is applied to the coil, current passes through the wire and creates a 
magnetic field. This magnetic field pulls the contacts together and holds them there until the current 
flow in the coil has stopped.  
Relays come in all varieties and types, but for the applications that concern us,  we will concentrate 
on the 

Single Pole Double Throw (SPDT) 12 Volts relay. 

 

Naming Convention: 

Usually the relay’s manufacturer will include an electrical diagram on the relay displaying the role of 
each terminal and how they interact with each other. 
These terminal numbers are standard, and can be used with any SPDT relay. 
 

85 & 86:

 The Coil. These inputs energize the coil when one is +12 Volts, and the other is Negative. 

They are usually non-polarized, so it does not matter which one is positive (+) or negative (-).  

87:

 Normally Open ( N/O). When the coil is energized, 87 is connected to 30. 

Содержание CT-3200

Страница 1: ...ed in Canada by Autostart A U T O M A T I C T R A N S M I S S I O N M U L T I C H A N N E L R E M O T E S T A R T E R S Y S T E M CT 3200 Installation Guide Table of Contents Introduction 2 Included i...

Страница 2: ...undesired operation of the device To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power EIRP is not...

Страница 3: ...rnal relays or modules added to the remote starter module are properly fused and diode isolated when testing the shock sensor never test on glass with an opened hand and never hit glass hard enough as...

Страница 4: ...ional ignitions accessories or starter wires must use external relays DO NOT JUMP WIRES at the ignition switch this will compromise the OEM electrical system 5 Pin Secondary Harness Wire Description 1...

Страница 5: ...programming menu see page 9 7 WHITE ORANGE Starter Kill Armed output The unit is equipped with a selectable passive or active arming starter kill circuit that will immobilize the vehicle when the sys...

Страница 6: ...tiple relays or modules are connected to the ground out wire ensure that they are all diode isolated in order to avoid feedback and damaging the vehicle 11 GREY N A This pin is not used leave empty 12...

Страница 7: ...makes the module go into the programming centre Once the module is in the programming centre the installer has no more than 20 seconds to get into one of the sub menus Failure to do so will result in...

Страница 8: ...ing into the programming option mode the parking lights will flash once twice depending on the option you have entered The unit will stay in programming mode until the hood pin switch or the brake ped...

Страница 9: ...starter kill engages This option should be selected ONLY if the starter kill is installed MODE 2 indicates default setting FUNCTION 1 Engine Run Time OPTION 1 4 minute Run Time in Gas Mode 9 minute in...

Страница 10: ...le 5 Testing Before putting back the vehicle together it is recommended to check that the system operates properly The following testing procedures should be used to verify proper installation and ope...

Страница 11: ...t uses three sets of pins Each set of ote Only one set of pins can be used at a time ote Only one set of pins can be used at a time pins has a function To activate one of the three possible 2nd output...

Страница 12: ...se Duration The Door Lock pulse dur default 4 sec LOCK and UNLOCK pulses or for a 7 10 sec LOCK pulse and two 1 4 second UNLOCK pulses used for double pulse disarm unlock systems In GAS mode the Mod m...

Страница 13: ...ting range This includes the metal in the car The shape of the po ge 13 The shape of the roof and A pillars brings about considerable radio frequency deflection in this case th fa relation to the remo...

Страница 14: ...market grommet when ever you drill a hole through the fire wall This will protect the wires from rubbing against the bare metal and possibly shorting out If you are installing an Alarm starter combo m...

Страница 15: ...all is complete and the vehicle can be put back together A basic introduction to the Relay What is a relay A device that responds to a small current or voltage change by activating switches or other d...

Страница 16: ...diode A diode installed between the coil terminals 85 and 86 could be internal or external To activate the coil on this type of relay make sure that the 12 Volts trigger is on the same terminal of th...

Страница 17: ...the park light switch and activates the wipers Where the connection was made from the start modules Park light output and the vehicle s park light circuit the OEM park light wire is cut to isolate th...

Страница 18: ...vehicle s OEM start wire is cut The side of the wire that is still connected to the Ignition switch becomes the Key Side of the starter wire The side of the wire that is still connected to the starte...

Страница 19: ...n relation to the remote control can affect the range Straight on standing in front of the vehicle generally gives you the greatest range the second best performance is from the back Using the remote...

Страница 20: ...ake an Auto Tach Adjustment Weak Tach signal Bad ground 7 The car starts by remote but then the starter re engages Check ground wire Is Tach programmed 8 The car starts on it s own Is the module in co...

Страница 21: ...ith the key again Does the vehicle have factory alarm keyless entry You might have to switch to a 433MHZ module Some GM Trucks Cavalier Sunfire Breeze Stratus Cirrus 22 Sometimes I have to press butto...

Отзывы: