Prosonic PRO-698 Скачать руководство пользователя страница 9

Access Control Instruction Manual 

 

 

6.4 LockCtrl  

Click “LockCtrl” in Settings menu, Enter the access control function. 

 

6.4.1 Time Setting  

 

"Time" refers to setting the time zone to allow open the door, It is an important part of access control 

settings. And up to 255 “time” can be defined.  it can be set to 6 time periods each "time", Each time 

zone refers to the valid time period within 24 hours, 6 time zones are "or" relationship, As long as the 

verification time can be meet one of them is valid. Each time zone format of "Time": hh:mm-hh:mm, 

Accurate to the every minute follow the 24-hour clock.   if the end time is less than start time (23: 57- 

23:56), The settings cannot be saved; Enter the "Time Setting", the screen as follows:  

Enter the "time1" settings, the screen as follows

  

For example: Allow the door to open at 04:00: -11:00,03:00-06:00,11:00-18:00

  

 

By analogy, you can define multiple time periods as needed.  

Note: the system default “time1” open all day, The newly registered us

er default time period is 

1, therefore, the newly registered users can verify success and open the door.  

 

6.4.2 Users to open  

“Users to open” confirm the number refers to the simultaneous needs of several users to confirm 

before they can open the door, For example: set the “Users to open” to 2, Any two users can open 

the door after verification is successful. The default is 1.  

6.4.3 Unlock Time  

“Unlock Time” refers to the device control to open or close the electric lock time, Set to "0"

turn off 

the lock control function, The unit is 1 second, the maximum can be set as 255. Press "OK" to enter 

settings, Press the number keys to enter the corresponding number, Press "OK" to exit and save the 

settings. The default is 5.  

Содержание PRO-698

Страница 1: ...User Manual PRO 698 Fingerprint Time Attendance and Access Control PRO 698 Fingerprint Time Attendence and Access Control...

Страница 2: ...ccess Control Instruction Manual 1 Access Control Manual 1 Notice for use 1 1 Access Control wiring diagram 1 2 Access Control External Power wiring diagram recommendation General Power wiring diagram...

Страница 3: ...ation height is confirmed the installation positioning template is affixed to the installation location According to the positioning template identifies drilling and fix it The red mark is the drillin...

Страница 4: ...the number Click the button to enter the main menu Click the button to enter the quick search operation Click the button on menu interface you can return to the initial interface quickly Click the bu...

Страница 5: ...Step 4 View records through the access control software to download the original records of equipment for data analysis 3 2 The initial interface and main menu After the device is connected to the po...

Страница 6: ...the initial interface 4 1 2 Password registration Click Password According to the hint enters the employee number and name Enter the same password twice to complete the registration then back to init...

Страница 7: ...rk and Lock Ctrl 6 1 Device Settings In Settings menu Click Device enter the device settings firmware Device No Device number 1 255 optional Language Switchable language Admins It can set up to 10 War...

Страница 8: ...mpted 6 2 2 Punch interval min In the set time repeated punching no logs generated 6 3 Network Click Network in Settings menu enter the network settings If you need to open real time monitoring To set...

Страница 9: ...ings the screen as follows For example Allow the door to open at 04 00 11 00 03 00 06 00 11 00 18 00 By analogy you can define multiple time periods as needed Note the system default time1 open all da...

Страница 10: ...ally used in banks and other important places 6 4 6 Turn Off Alarm After the alarm is triggered eliminate the wrong operation and stop the alarm by clicking this item 6 4 7 Tamper Alert Tamper alert h...

Страница 11: ...iew user registration admin registration fingerprints registration ID IC card registration password registration attendance logs and other information 7 3 Dev Info Information such as manufacturer dat...

Отзывы: