Access Control Instruction Manual 

 

 

6.4.4 Lock Type Set  

There are three types of Lock Type Set: NO, Open, Close; "NO" means not using the door sensor; 

"Close" means the door magnetic is close status, If the door is open status, an alarm occurs; "Open" 

means the door magnet is open status, If the door is closed more than the set time, an alarm occurs, 

the default is NO.  

Alarm Delay: After the door is opened or closed, Start detection the setting time of door status. 

The maximum can be set 255 seconds, “0” means to turn off the door magnetic delay alarm. 

 

6.4.5 Anti-Pass  

Require the verifier to come in from a door and must go out from this door, Records must be strictly 

corresponding to have entered and exited, Prevent other people trail in behind you. 

 

Mainly use for 

two-way verification of the door(Need to verify both in and out), In other words, If you go out without 

verification, Then you can no longer enter from this door. Mainly to prevent someone following others 

to go out, then secretly sneak into, normally used in banks and other important places.  

6.4.6 Turn Off Alarm 

 

After the alarm is triggered, eliminate the wrong operation and stop the alarm by clicking this item.  

6.4.7 Tamper Alert  

Tamper alert has two statuses: “Yes” and “No”. "Yes" refers to turning on tamper alert function, an 

alarm occurs when the device is removed. "No" refers to the closure of tamper alert function, When 

the machine is removed, no alarm occurs, Tamper alarm must be set to "Yes" after installation of the 

machine, The default is "Yes".  

6.4.8 Wiegand Output 

 

Wiegand output includes: user ID and Card number;   

6.4.9 Wiegand Format  

Wiegand format includes: Wiegand 26, Wiegand 34; "Wiegand 26" refers to Wiegand output signal is 

processed, Output in the form of Wiegand 26; "Wiegand 34" refers to Wiegand output signal is 

processed, Output in the form of Wiegand 34;   

6.4.10 Door Status 

 

Door status refers to set the mark of access records for user, in or out.  

7. View Info 

Click “View Info” in Settings menu, View info includes: User Log, Reg.Info and Dev.Info. 

 

7.1 User Log  

Click “User Log”, Enter the corresponding user ID and press "OK

", Select start and end dates, Time 

format: YYYY/MM/DD, Press "OK" to check the user attendance records for the period of time.  

Содержание PRO-698

Страница 1: ...User Manual PRO 698 Fingerprint Time Attendance and Access Control PRO 698 Fingerprint Time Attendence and Access Control...

Страница 2: ...ccess Control Instruction Manual 1 Access Control Manual 1 Notice for use 1 1 Access Control wiring diagram 1 2 Access Control External Power wiring diagram recommendation General Power wiring diagram...

Страница 3: ...ation height is confirmed the installation positioning template is affixed to the installation location According to the positioning template identifies drilling and fix it The red mark is the drillin...

Страница 4: ...the number Click the button to enter the main menu Click the button to enter the quick search operation Click the button on menu interface you can return to the initial interface quickly Click the bu...

Страница 5: ...Step 4 View records through the access control software to download the original records of equipment for data analysis 3 2 The initial interface and main menu After the device is connected to the po...

Страница 6: ...the initial interface 4 1 2 Password registration Click Password According to the hint enters the employee number and name Enter the same password twice to complete the registration then back to init...

Страница 7: ...rk and Lock Ctrl 6 1 Device Settings In Settings menu Click Device enter the device settings firmware Device No Device number 1 255 optional Language Switchable language Admins It can set up to 10 War...

Страница 8: ...mpted 6 2 2 Punch interval min In the set time repeated punching no logs generated 6 3 Network Click Network in Settings menu enter the network settings If you need to open real time monitoring To set...

Страница 9: ...ings the screen as follows For example Allow the door to open at 04 00 11 00 03 00 06 00 11 00 18 00 By analogy you can define multiple time periods as needed Note the system default time1 open all da...

Страница 10: ...ally used in banks and other important places 6 4 6 Turn Off Alarm After the alarm is triggered eliminate the wrong operation and stop the alarm by clicking this item 6 4 7 Tamper Alert Tamper alert h...

Страница 11: ...iew user registration admin registration fingerprints registration ID IC card registration password registration attendance logs and other information 7 3 Dev Info Information such as manufacturer dat...

Отзывы: