ICX35-HWC ♦ Industrial Cellular Gateway
ICX35-HWC Webpage
3G/4G LTE
User Manual
ProSoft Technology, Inc.
Page 51 of 127
Connection Recovery
The Connection Recovery is used to trigger a reboot of the ICX35-HWC when there
is a loss of connectivity or if the ICX35-HWC stops communicating. The reboot
trigger conditions are:
Loss of communications to a known endpoint WAN IP
Loss of communications to Belden Horizon
Parameter
Description
Enable Connection Recovery Enables the Connection Recovery feature.
Endpoint Address
Configure a known WAN IP address (Default 8.8.8.8, a known Google
DNS address). If the ICX35-HWC is not able to reach this WAN IP and
the
Endpoint Timeout
parameter is true, then the ICX35-HWC will
reboot.
Belden Horizon Timeout
The time interval (in minutes) after which the ICX35-HWC will reboot if
there is no connectivity with Belden Horizon. Maximum value: 1439 (23
hours, 59 minutes).
Endpoint Timeout
The time interval (in minutes) after which the ICX35-HWC will reboot if
the
Endpoint Address
is not reachable.
Success Threshold (%)
Percentage of successful attempts to reach the endpoint/ Belden
Horizon, for which the ICX35-HWC does not reboot.