3
2-3-2.(ACV)
Range Accuracy
Resolution
2V 1mV
20V 10mV
200V
±(0.8%+5d)
100mV
750V ±(1.2%+10d) 1V
Input Impedance: 10 M
Ω
at all the ranges.
Overload protection: 1000V DC or AC peak value.
Frequency Response:
(
40~200
)
Hz at the Range below 20V
(
40~100
)
Hz at the Range 200V~750V
Display: average value response (RMS of sine wave)
2-3-3.
(
DCA
)
Range Accuracy
Resolution
2mA 1uA
20mA
±(0.8%+10d)
10uA
200mA ±(1.2%+8d)
100uA
10A ±(2.0%+5d)
10mA
Max input voltage drop: 200mV
Max input current: 10A (less than 10 seconds)
Overload protection: 0.2A/250V self-resettable fuse, 10A/250V
fast-blown fuse
2-3-4.
(
ACA
)
Range Accuracy
Resolution
20mA ±(1.0%+15d)
10uA
200mA ±(2.0%+5d)
100uA
10A ±(3.0%+10d)
10mA
Max measurement voltage drop: 200mV
Max input current: 10A (less than 10 seconds)
Overload protection: 0.2A/250V self-resettable fuse, 10A/250V
Содержание MT-1270
Страница 14: ...MT 1270 3 1 2 26mm LCD A D 1 IEC1010 2 36V 36V 25V 3 4 5 6 7 8 13...
Страница 19: ...1 2 HOLD Hold Hold 3 4 200mA 5 10A 6 7 8 POWER 9 10 LED 1 COM V Hz 2 DCV 1 2 1 1 COM V Hz 2 ACV 18...
Страница 20: ...19 1 2 1 1 COM mA 200mA 10A 10A 2 DCA 1 2 1 3 200mA 10A 10A 1 COM mA 200mA 10A 10A 2 ACA 1 2 1 3 200mA 10A 10A...
Страница 21: ...20 1 COM V Hz 2 1 1 1M 2 3 1 mA COM 2 1 2 1 3 4 5 6 1uF 1000nF 1nF 1000pF...
Страница 22: ...1 COM V Hz 2 1 10Vrms 2 3 4 250V 1 COM V Hz 2 3 70 20 COM mA hFE 1 hFE 2 COM mA 3 NPN PNP 15 POWER 21...
Страница 23: ...1 2 3 4 4 1 9V LCD 4 1 1 4 1 2 9V 9V 4 1 3 22...
Страница 24: ...23...