FITTING INSTRUCTIONS: 

 
Fitting The Pre-Plumbed RO System 

Use the bracket as a template to mark the position of the unit on a suitable wall or cupboard panel. Allow a 
minimum of 40mm clearance below the filter bowls to allow for filter change out. Drill and plug two holes and 
screw in 2 screws (not supplied) allowing the screw heads to protrude from the wall by approx. 5mm. Place 
the bracket over the screws and slide to left or right (as preferred) to lock bracket in position.

 

 

Fitting The Tap

 

Select  a  suitable  position  on  the  work  top  or  corner  of  the  sink.  Before  drilling  the  hole,  check  there  is 
nothing directly underneath that could be damaged i.e. water or  waste pipes, cables etc. Also make sure 
that there is room for the locating washer and that you can physically reach the tap stud to connect the nut. 
Use a centre punch to mark the location of the hole to be drilled. Drill a 3mm pilot hole. Enlarge the hole to 
11mm  (7/16”).  If  you  are  drilling  through  stainless  steel,  deburr  and  rough  edges  around  the  hole.  Wipe 
clean  with  a  soft  cloth.  Check  that  the  tap  stud  fits  easily  through  the  hole.  Place  the    nut  and  then  the 
plastic olive over the blue tube  leaving 3-4mm of blue tube showing. Push tube insert into the open end of 
the blue tube. Tighten the nut onto the end of the tap stud. 
The tap is off when the lever is pointing down. Turn lever to the right for flow.  
 

Fitting The Saddle Tapping Valve 

(Red tubing attached) 

Although  not  essential,  we  recommend  that  you  turn  off  the  cold  water  stopcock  and  relieve  the  water 
pressure by opening cold water tap. If the stopcock is under the sink, fit the valve after the stopcock. The 
valve must be fitted on the cold water supply copper pipe only, (if you are uncertain, run the hot tap for a 
minute and feel the pipes under the sink to distinguish the cold pipe). 
Do not fit the valve on a bend, a join or where there is solder on the copper pipe. Attach the clamp around 
the pipe and tighten the clamp bolt to ensure a water tight seal. Do not over tighten the clamp bolt as this 
may distort the water pipe. Firmly push the open end of the red tubing attached to the saddle tapping valve 
into the collar on the front of the sediment filter housing (Stage 1).

 

Note: 

Later designs have the red tubing already permanently fitted to the valve. The saddle tapping valve 

supplied  with  the  Reverse  Osmosis  System  is  designed  to  comply  with  British  plumbing  codes.    (See 
‘System Start Up’ Section for further details regarding the saddle tapping valve.)

 

 

Fitting The Tank Ball Valve

 

Connect  the  ball  valve  to  the  threaded  connector  on  the  tank,  make  sure  it  is  tight  but  not  over-tight. 
Connect the yellow tubing to the tank ball valve. Turn the tank ball valve off.  ie handle at 90 degrees to the 
tube.

  Note:

  The  air  valve  on  the  lower  side  of  the  storage  tank  has  been  preset  at  8-10  psi  by  the 

manufacturers.  In time it may need topping back up to pressure—see troubleshooting. 

 

Mounting The Drain Clamp 

Connect the red tubing to the output of the flow restrictor. Turn off the membrane flush valve. 

Note: 

The drain clamp will fit most standard drain pipe 1 1/2” diameter. It should be installed above the trap/

u-bend - between the sink and the U Bend and on the vertical or horizontal tailpiece. If a waste disposal unit 
is fitted, the drain clamp must not be fitted into the same waste pipe.  It is important that the drain is 

NOT

 

connected into the foul side of the sink U Bend. 
Position the drain saddle in the desired location by hand, mark a spot on the waste pipe through the tube 
connector,  remove  saddle.  Drill  1/4”  (6.3mm)  hole  into  the  drain  pipe  above  the  water  line  of the  trap/U-
bend. Align the hole drilled in the drain pipe with the drain saddle using a drill bit. Make sure to align drain 
saddle to drilled hole. Attach self adhesive seal on the inside of the saddle over the drain hole. Attach drain 
saddle  to  waste  pipe  and  tighten  the  two  screws  evenly.  Connect  the  red  tubing  to  the  drain  push  fit 
connector.  

Содержание RP65139715

Страница 1: ...22 377367 email sales prosep co uk www prosep co uk Prosep Filter Systems Ltd Unit G19 River Bank Way Lowfields Business Park Elland West Yorkshire HX5 9DN INSTALLATION OPERATING INSTRUCTIONS SIX STAGE REVERSE OSMOSIS UNIT WITH PUMP RP65139715 ...

Страница 2: ... manual before proceeding with the actual installation Pay particular attention to all warnings cautions and notes Failure to do so could result in personal injury or damage to equipment or other property System and installation need to comply with local laws and regulations If you have questions please contact us CONTENTS PAGE DESCRIPTION 3 Checklist 3 Recommended Tools List 4 Product Specificati...

Страница 3: ... Prosep Filter Systems Ltd Unit G19 River Bank Way Lowfields Business Park Elland West Yorkshire HX5 9DN RP65139715 Reverse Osmosis Water storage tank with valve Tap assembly TOOLS LIST 1 Drill 2 Drill bits 1 8 1 4 7 16 3 1 2 and 9 16 spanner or adjustable 4 Philips screwdriver 5 Utility knife ...

Страница 4: ...FICATION 1st Stage 5 micron sediment filter HTPP DM 05N9 8 Change 6 monthly 2nd Stage Activated granular carbon type GAC GAC 9 Change 6 monthly 3rd Stage Carbon block cartridge type PAC PAC 9 Change 6 monthly 4th Stage Reverse Osmosis membrane 75 GPD 1812 75GPD As needed 2 years 5th Stage Post RO carbon filter AICRO 6 monthly 6th Stage Remineraliser and pH balance unit AIMCRO QC 6 monthly FLOW DIA...

Страница 5: ...r the sink to distinguish the cold pipe Do not fit the valve on a bend a join or where there is solder on the copper pipe Attach the clamp around the pipe and tighten the clamp bolt to ensure a water tight seal Do not over tighten the clamp bolt as this may distort the water pipe Firmly push the open end of the red tubing attached to the saddle tapping valve into the collar on the front of the sed...

Страница 6: ...urn the tap handle to the closed position and let the refilling process begin This process could take 2 4 hours to complete After the second tank is filled you may enjoy the pure water Check for leaks daily for the first week and periodically thereafter You may notice that the water may be milky coloured during the first week This is caused by air bubbles in the water released from the carbon filt...

Страница 7: ...he system and the other hand to turn the wrench clockwise to separate the head from the bowl NOTE IF IT IS TOO TIGHT TO OPEN THE HOUSING YOU MAY TRY TO UNPLUG THE FITTING BETWEEN THE RED TUBING AND THE SYSTEM IN ORDER TO REDUCE THE AIR AND WATER PRESSURE INSIDE THE HOUSING e To change the sediment cartridge and the pre carbon cartridge you need to open the clear and opaque housings remove the used...

Страница 8: ...all amount of water in storage tank System just starting up Air pressure in storage tank is low Normally it takes 2 3 hours to fill the tank Low water pressure and or temperature can reduce production rate Add pressure to storage tank The pressure should be 8 10 psi when the tank is empty Slow production Low water pressure Crimps in tubing Clogged pefilters Fouled membrane Make sure tubing is stra...