INTENDED PURPOSE
The Propulse NG Electronic Ear Irrigation System is intended to:
a) Facilitate the removal of cerumen and foreign bodies that
are not hygroscopic from the auditory meatus.
b) Remove discharge, keratin or debris from the external
auditory meatus by irrigation with warm water.
Reasons for using this procedure are to:
a) Correctly treat otitis externa where the meatus is obscured
by debris.
b) Improve conduction of sound into the ear, where impacted wax is
believed to be the cause of a hearing defect.
c) Examine the external auditory meatus and the
tympanic membrane.
d) Remove a cause of discomfort.
This procedure should ONLY be carried out by a suitably
trained clinician.
WARNINGS AND CAUTIONS
l
This manual must be read and understood before the
Propulse NG Electronic Ear Irrigation System is used.
l
Only suitably trained staff should use the device.
Mirage can advise on the availability of training
courses offered by relevant organisations.
l
The Propulse QrX Tip is “Single Use” and should be
disposed of in accordance with local authority guidelines
after use.
l
The Propulse NG Electronic Ear Irrigation System must not
be immersed in water.
l
Only clean the device as specified in this manual
(See page 13).
l
If any changes in performance occur, turn off the Propulse
NG Electronic Ear Irrigation System, disconnect from the
mains electricity supply and DO NOT use (See page 14).
l
The device has no user serviceable parts (See page 14).
l
Use recommended Propulse accessories only.
l
Do not use Propulse accessories with other devices.
l
If the device is to be used for domestic visits, it is strongly
recommended that a Propulse Carry Case is used to prevent
damage and contamination.
l
The Propulse NG Electronic Ear Irrigation System is not user
repairable and should be returned to your Propulse supplier
or the Mirage Health Group Certified Service Centre
(UK customers only) for service and/or repair. It is
recommended that the Propulse NG Electronic Ear Irrigation
System is serviced annually.
Please note:
Damage caused to your Propulse NG Electronic
Ear Irrigation System by the use of accessories, consumables or
service agents not recommended by Mirage Health Group, will
invalidate your warranty.
l
DO NOT IRRIGATE
the ears if:
a) Consent is not given and/or the patient is uncooperative.
b) Previous complications occurred following this procedure.
c) There is a history of a middle ear infection in the last
six weeks.
d) The patient has undergone ear surgery (apart from
grommets that have extruded at least 18 months previously
and the patient has been discharged from the ENT dept).
e) The patient has a perforation or there is a history of a
mucous discharge in the last year.
f) The patient has a cleft palate (repaired or not).
g) In the presence of acute otitis externa; an oedematous ear canal
combined with pain and tenderness of the pinna.
h) If patient complains of pain -
STOP IMMEDIATELY
.
DESCRIPTION
1. Water Container/Reservoir
(Marked for indication only)
2. Propulse QrX Tip (Single Use)
3. QrX Handle
4. Lid
5. Water Jet ‘Stop Button’
6. Pressure/Flow Control Knob
7. Footswitch Power Switch
8. Charging/Mains Power Light
9. Power Status Light
10. Footswitch Socket
11. Power Adaptor Socket
12. Footswitch
11. 10.
1. 4.
7.
12.
8.
9.
6.
2.
5.
3.