SECTION 5
Pronar T669/1
5.45
FAULT
CAUSE
REMEDY
Incorrect main or parking
brake adjustment
Regulate setting of expander arms
Excessive heating of axle
hubs
Worn brake linings
Change brake shoes
Improper hydraulic oil
viscosity
Check oil quality, make sure that
the oil in both machines is of the
same type. If necessary change
oil in tractor or in trailer.
Insufficient tractor hydraulic
pump output, tractor
hydraulic pump is damaged
Check tractor hydraulic pump.
Damaged or contaminated
ram cylinder
Check cylinder ram piston
(bending, corrosion), check ram
cylinder for tightness (piston seal),
in case of need repair or replace
ram cylinder.
Excessive cylinder ram
loading
Check mechanism controlled by
ram cylinder for mechanical
damage.
Incorrect hydraulic
system operation
Damaged hydraulic
conduits
Check and ascertain that hydraulic
lines are tight, not fractured and
properly tightened. If necessary
replace or tighten.