SECTION 5
Pronar T314, Pronar T315, Pronar T316
5.19
¨
In the event, that the valve stem resists returning to its setting, then the whole
drain valve must be unscrewed and cleaned, or replaced (if it is damaged) -
see section
CLEANING DRAIN VALVE
.
Draining water from air tank:
•
every seven days of use.
5.4.2 CLEANING DRAIN VALVE
DANGER
Before dismantling drain valve release air from tank.
Required service actions
¨
Reduce pressure in air tank.
Ö
Reduction of pressure in tank is achieved by tilting the drain valve
mandrel.
¨
Unscrew valve.
¨
Clean valve, purge with compressed air.
¨
Change copper seal.
¨
Screw in valve, fill air tank, and check tank tightness.
Cleaning valve:
•
every 12 months (before winter period).
Содержание T314
Страница 4: ......
Страница 9: ...SECTION 1 BASIC INFORMATION ...
Страница 22: ...Pronar T314 Pronar T315 Pronar T316 SECTION 1 1 14 ...
Страница 23: ...SECTION 2 SAFETY ADVICE ...
Страница 39: ...SECTION 2 Pronar T314 Pronar T315 Pronar T316 2 17 FIG 2 4 Locations of information and warning decals ...
Страница 40: ...Pronar T314 Pronar T315 Pronar T316 SECTION 2 2 18 ...
Страница 41: ...SECTION 3 DESIGN AND OPERATION ...
Страница 53: ...SECTION 4 CORRECT USE ...
Страница 68: ...Pronar T314 Pronar T315 Pronar T316 SECTION 4 4 16 ...
Страница 69: ...SECTION 5 MAINTENANCE ...
Страница 92: ...Pronar T314 Pronar T315 Pronar T316 SECTION 5 5 24 FIG 5 11 Lubrication points of the slurry tanker ...
Страница 106: ...Pronar T314 Pronar T315 Pronar T316 SECTION 5 5 38 ...
Страница 107: ...NOTES ...
Страница 108: ... ...
Страница 110: ...ANNEX B ...