promobot ThermoControl Plus Скачать руководство пользователя страница 3

ThermoСontrol Plus (

ThermoСontrol

 or 

device

) is a screening station for automatic contactless 

face temperature measurement with facial recognition functionality.

The device performs a facial skin temperature measurement at a distance of up to 25 cm 
without interaction with another person or with the device’s surface. It can be set up to 
automatically save the person’s photo and the results in a database. It will notify the operator 
if the user’s face temperature is above average. It can store the results with the person’s full 
name and be integrated with access control systems. The station adjusts its sensor according 
to the user’s height to ensure the proper temperature measurement.

A human body temperature is not constant. It differs not only from person to person, but 
from one part of the body to another. For the most accurate results, specialists recommend 
measuring temperature in the armpit or rectally. In a high throughput area, these options are 
not viable. One of the best solutions is a contactless temperature measurement taken from 
a person’s face.

ThermoСontrol is a screening station made for automatic contactless face temperature 

measurements.

Human  faces  don’t  have  a  consistent  temperature  throughout  the  surface  (Fig.  1).  The 

manufacturer considered that when developing the screening logic. The device measures 
the temperature in 10 points of a person’s face. A temperature sensor moves from the top to 
the bottom of the face, starting at the forehead and ending on the lips, determining the most 
precise temperature rate. The most accurate measurement is provided when the forehead is 

uncovered (Fig. 2).

ThermoСontrol does not measure temperature orally, in the armpit or rectally.

Human’s face may become colder or hotter depending on weather conditions. It is not 
recommended to measure temperature immediately upon entering the building; user must 
wait until face temperature evens out.

1. General information

1.1. Description and primary functions

1.2. How ThermoСontrol Plus 

 

measures temperature 

Fig. 1 

Face heatmap

36°C

30°C

4

5

Promobot ThermoСontrol Plus. User Manual

Содержание ThermoControl Plus

Страница 1: ...Promobot ThermoСontrol Plus Autonomous Screening Station for Temperature Measurement www thermocontrol ai PROMOBOT CORP 86 Tomlinson Rd B1 Huntingdon Valley PA 19006 1 855 5 ROBOTS info thermocontrol ai ...

Страница 2: ...ecting device via Wi Fi 29 Temperature settings 30 Save photos to the database 32 Language settings 33 Sound settings 34 Welcome Screen configuration 35 2 2 7 Additional settings 36 Device registration 36 Removing device from the server 38 Device information overview 40 Updates installation 42 Additional languages 43 Single spot measurement 44 Light mode 45 Advanced Settings 47 2 3 Guidelines 48 2...

Страница 3: ...e options are not viable One of the best solutions is a contactless temperature measurement taken from a person s face ThermoСontrol is a screening station made for automatic contactless face temperature measurements Human faces don t have a consistent temperature throughout the surface Fig 1 The manufacturer considered that when developing the screening logic The device measures the temperature i...

Страница 4: ...nline video calls Available The manufacturer reserves the right to change the location of the product s built in computing module both inside and outside of the device s casing Table 1 Technical characteristics The following factors affect a healthy person s body temperature individual metabolism age small children generally have a higher body temperature clothes outside temperature a time of day ...

Страница 5: ...r any compatible materials displays instructions during the measurement process displays measurement results color codes the results green color if the temperature is normal red if it is above normal logs a person s photo and the measurement result and saves them in the database on a server is remotely monitored via web service notifies the station operator in case of high low temperature via the ...

Страница 6: ...ce DO NOT operate the station with unstable power grid voltage 2 Intended use 2 1 Usage limits 2 2 1 Preliminary safety measures 2 2 Assembly setup and launch Before the device is assembled all of its main elements must be removed from the soft packaging and checked for completeness Package contents Table 2 include Table 2 Package contents 2 2 2 Assembly Name Quantity Standing base a b 1 pc Thermo...

Страница 7: ...Fig 4 1 Package contents pt 1 Fig 4 2 Package contents pt 2 refer to pic 10 13 if a rear panel is angled refer to pic 10 1 13 1 if a rear panel is rounded 12 13 Promobot ThermoСontrol Plus User Manual ...

Страница 8: ...Numbers next to the images indicate the assembly steps These steps must be performed in the order presented The assembly process involves lifting heavy objects and circuit wiring Please keep that in mind before getting started 14 15 Promobot ThermoСontrol Plus User Manual ...

Страница 9: ...5 7 6 8 16 17 Promobot ThermoСontrol Plus User Manual ...

Страница 10: ...9 10 10 1 installing angled panel installing rounded panel 18 19 Promobot ThermoСontrol Plus User Manual ...

Страница 11: ...11 12 20 21 Promobot ThermoСontrol Plus User Manual ...

Страница 12: ...13 13 1 14 installing angled panel installing rounded panel 14 1 14 4 14 2 14 5 14 3 14 6 22 23 Promobot ThermoСontrol Plus User Manual ...

Страница 13: ...the guide frame to adjust the height Set the guide block to one of 13 positions Table 3 shows what heights are detected depending on the guide block s position Upper and lower thresholds mean maximum and minimum height respectively The thermal sensor will scan the temperature within these thresholds Average column shows the recommend ed height of the user for each position Numbers are shown from h...

Страница 14: ...east one minute before they take the measurement Another method of correcting the temperature after entering the building is to have a separate room with an air temperature of 20 23 C A person must remain in that room for one minute or more upon entering the testing area During the operation a personnel member uses the web service to control the station This service is accessed through the Interne...

Страница 15: ...tab Fig 8 The station has to be connected to the Internet to fully function It can be connected to a wireless network or via Ethernet cable Connecting device via Wi Fi 1 For wireless connection specify the name SSID of a wireless network Tap the Search button and select one of the available networks from the list Afterward enter your network password in the Enter password field Fig 9 2 2 6 Initial...

Страница 16: ...lor indication values for measurement result display Color indications are set up separately for normal and increased temperatures Fig 10 Temperature settings If the person s temperature is normal an active Color indication for normal temperature toggle will present the measurement result with a green color If the person s temperature is above threshold value an active Color indication for high te...

Страница 17: ...les saving photos to the database of measurement results Switch to the Advanced Settings section to access the setting Fig 11 The setting is enabled by default Language settings Select the Primary language for user interface voice prompts and Service menu If necessary set up to two additional languages for text hints 32 33 Promobot ThermoСontrol Plus User Manual ...

Страница 18: ...ame the file welcome where is one of the supported file types for the Welcome Screen Insert the flash drive into the ThermoСontrol USB port and press Update button in the Welcome Screen section Wait for the file to be uploaded to the station 1 The Voice prompts setting enables voice prompts By default the Voice prompts setting is disabled 2 The Sound effects setting enables sounds for measurements...

Страница 19: ...evice button After tapping the Add new device button two registration options will appear sign up with a new account or sign in using an existing account Fig 17 Tap Yes to register the device using an existing account A login window will appear Use account credentials to log into the monitoring service Fig 18 Fig 16 Add new device in the Account section Fig 17 Registration options Fig 18 Login win...

Страница 20: ...w user information will appear Fig 19 By default the username and password for the new accounts are matching To remove the device tap the Account button then tap Remove Fig 20 The Yes button becomes available in 4 seconds Fig 22 Tap Yes to remove the device A confirmation window will appear Fig 21 Fig 19 New user information window Fig 20 Remove device in the Account section Fig 21 Remove the devi...

Страница 21: ...the web service account test the measurement send process Close the service menu by tapping the icon in the upper left corner Follow the instructions on the screen Measurement sending status is displayed in the upper left corner of the screen on the interface status panel Fig 24 If the icon is gray the device has not sent any measurement results since its activation Fig 22 Active Remove the device...

Страница 22: ...rsion window Updates installation Software updates can be installed from the service menu Tap the Update button in the upper right corner of the service menu to bring up the current version window Fig 25 A notification will appear if updates are available Updates can be installed over the Internet or from the USB flash drive Fig 26 42 43 Promobot ThermoСontrol Plus User Manual ...

Страница 23: ...hm Results might differ from a pyrometer which measures temperature in a single spot on the face To compare a single spot measurement of the device with the pyrometer select Test Mode in the Temperature section Fig 28 29 No instructions will be shown during the Test Mode Measure temperature as if using the pyrometer Bring forehead to the sensor at the same distance as for the pyrometer A measureme...

Страница 24: ...tion shows a notification window with a custom message To continue measuring the user must tap the Proceed button Face mask notification a notification reminds the user to wear a mask Fig 32 Advanced Settings Bring your forehead to the sensor Toggles differ depending on the selection If the Face recognition toggle is disabled then the next setting will be shown as Face detection instead of Livenes...

Страница 25: ...he station a user steps on the standing base facing the main section of the device If a person s forehead is placed incorrectly in relation to the range sensor the station will inform the person and display a screen with advice on a proper measurement position Fig 34 35 2 3 1 Operator guidelines 2 3 2 User guidelines 2 3 Guidelines Fig 33 Station main screen Fig 34 Position adjustment screen Fig 3...

Страница 26: ...mendation screen accompanies the process Fig 36 Once a measurement has been taken the results are displayed Color coding is used for better result identification Green indicates normal body temperature Fig 37 Red indicates increased body temperature Fig 38 Fig 36 A recommendation screen informs user to stand still during the process Fig 37 Measurement results body temperature is normal Fig 38 Meas...

Страница 27: ... to any emergency situations that could cause damage to individual property any state and public property the environment or the life and health of individuals This manual does not include nor imply any specific guidelines for operators on that matter In case of emergency operation i e if the operating conditions of ThermoСontrol Plus station provided in this manual exceed the resistance to the ex...

Страница 28: ...spare parts and accessories due to normal wear and tear 7 The manufacturer will eliminate all of the encountered defects that arise during the warranty period free of charge as well as replace the station entirely if the defects did not arise as a result of violating the usage or storage guidelines by the client Warranty repairs are carried out by the manufacturer s service center Unscheduled main...

Страница 29: ...www thermocontrol ai ...

Отзывы: