Vess R3604fi Fiber Channel SAN data connections
Fibre Channel SAN data path
The Vess R3604fi features 16Gb Fibre Channel. The Fibre Channel data network requires the following items:
•
A Fibre Channel connection in each host PC or server
•
An SFP transceiver for every SFP (Fibre Channel) port in the connection (subsystem, switch, HBA),
16Gb
SFP transceivers are recommended for best performance.
•
A Fiber Channel switch (not required for direct attached connection)
•
Fiber Optic cabling
Fibre Channel SAN connections
For the 16Gb Fibre Channel storage area network (SAN):
1. For servers equipped with Fibre Channel HBA cards, connect Fiber Optic cables between the Fibre
Channel ports in both host PCs or servers and the ports on a Fibre Channel network switch.
2. Connect Fiber Optic cables between the Fibre Channel port on the Vess R3604fi controllers and a Fibre
Channel port on a Fibre Channel switch or Fibre Channel capable switch (SFP).
If you have multiple Vess R3604fi subsystems, host PCs or servers, repeat the steps as required.
29
Promise
Technology
Hardware Setup