Minent ProMix
‘S & C’ Polymer Feeder
ProMix Series S&C User Manual
2.12
Operation Configuration
Set points
Control of the neat polymer feed pump is set by the
System Start
and
Polymer Pump
switches located on the ProMix control panel door. The type of polymer, either
emulsion
or
Mannich
, and the operation, either
Local
or
Remote,
are selected via the controller keypad
or browser interface. Refer to the ProMix Mode and Polymer charts in section 1.6.
NOTE: In Batch mode the ProMix feeder adjusts the pump speed as the measured Primary
& Post dilution flow rates vary to maintain the setpoint polymer concentration.
Feed Verification
Feed verification ensures that the polymer pump is actually delivering polymer by monitoring
the output of the pump. Sometimes a thermal flow switch is employed for this purpose as an
optional feature for ‘other’ type pumps selection. The Gamma XL pump utilizes an integral
relay for feed verification. See section 2.13 for further details.
Pump Calibration
Before placing the ProMix system in operation the polymer pump should be calibrated at
maximum dosing and the resultant gph rate entered into the configuration menu for pump
size. A calibration cylinder is provided on most ProMix systems to assist in the calibration of
the polymer pump. The following procedure should be followed to calibrate a Gamma XL
type pump, assuming all installation requirements are met:
1. Configure pump for manual operation, set desired suction viscosity spm, and set stroke
length to 100%.
2. Fill calibration cylinder to top mark by manipulating valves & pump to allow neat polymer into
the cylinder. Manually fill the calibration cylinder if it is not possible to use the pump output.
3. Keep ProMix feeder connected to the actual system so that maximum application back
pressure is realized.
4. Open primary dilution water valve so that the mix chamber fills when system is started.
5. Manipulate pump valves so that pump suction is connected to the calibration cylinder only.
6. Manually run pump at maximum rated strokes per minute and time the calibration column
drawdown for at least 30 seconds taking note of beginning and end marks. Calculate the gph
pump rate from the volume and time.
7. Using the controller keypad, enter the calculated pump rate in gph
8. Place the pump back into the analog mode.
Содержание ProMix C
Страница 44: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual General Mechanical Layout ProMix C DA...
Страница 46: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual P N 7747255 Mixing Chamber Components...
Страница 50: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual B 2 Control Panel Drawings...
Страница 51: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual...
Страница 52: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual...
Страница 53: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual...
Страница 54: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual...
Страница 55: ...ProMinent ProMix S C Polymer Feeder ProMix Series S C User Manual...