13.7 Installation height
Data
Value Unit
Maximum installation height*:
1000 m above
standard
zero
* with standard pumps: Fit at higher installation heights at your own
risk.
with ATEX pumps: We urgently advise that you contact a specialist
for ATEX motors at higher installation heights!
13.8 Motor data
Identity code
specification
Phases, protec‐
tion
Rated voltage
Mains fre‐
quency
Rated output
Remarks
S
3-phase, IP 55
220-240 V /
380-420 V
50 Hz
0.75 kW
250-280 V /
440-480 V
60 Hz
0.75 kW
R
3-phase, IP 55
230 V / 400 V
50/60 Hz
1.5 kW
with PTC, speed
adjustment range
1:20 with external
fan 1-phase 230
V; 50/60Hz
V0
1-phase, IP 55
230 V ±
50/60 Hz
1.1 kW
Variable speed
motor with inte‐
grated frequency
converter
L1
3-phase, II2GEx‐
eIIT3
220-240 V /
380-420 V
50 Hz
0.75 kW
L2
3-phase, II2GEx‐
deIICT4
220-240 V /
380-420 V
50 Hz
0.75 kW
with PTC, speed
control range 1:5
P1
3-phase, II2GEx‐
eIIT3
250-280 V /
440-480 V
60 Hz
1.0 kW
P2
3-phase, II2GEx‐
dIICT4
250-280 V /
440-480 V
60 Hz
0.75 kW
with PTC, speed
control range 1:5
V2
3-phase, II2GEx‐
deIICT4
400 V ±10%
50/60 Hz
1.5 kW
EX-variable speed
motor with inte‐
grated frequency
converter
Electrical data
Technical data
78
Содержание Makro TZ
Страница 45: ...Install the other units in line with their documentation Other units Installation 45...