Unusual noises.
Cause:
Recommended measure:
The air pressure is too high.
Adjust the air pressure.
The pump is blocked with foreign bodies, which
are larger than the permitted diameter (< 3 mm).
Dismantle, check and clean the pump housing.
Unusual vibrations.
Cause:
Recommended measure:
The connection elements and the fastening of the
pump are loose.
Check each connecting element and tighten the
screws.
The air pressure is too high.
Adjust the air pressure.
The different valves are vibrating or fluttering.
Adjust the air pressure. Adjust the feed pressure.
Air bubbles in the feed chemical.
Cause:
Recommended measure:
The diaphragm is faulty
Remove and check the pump and replace the dia‐
phragm.
Suction hose loose or broken.
Fasten or replace the suction hose.
Leaks or fluctuating air pressure between 3 ... 8 bar.
Cause:
Recommended measure:
Close directional valve.
Replace the components of the directional valve.
Pump does not start. No regulated air pressure.
Cause:
Recommended measure:
Immovable air pressure sensor.
Replace the air pressure sensor.
Close directional valve.
Replace the components of the directional valve.
Maintenance of the double diaphragm pump
22