5.5 "Water flow" circulation flow control
To monitor the circulation, as a dry-run protector for the corre‐
sponding circulating pump, it is possible to integrate a flow control
(
[Water flow 1] or [Water flow 2]), e.g. a paddle switch. The contact
of the flow control is connected in the F module to digital input
[K02] (with 4-point level measurement) or the digital input [K04]
(with a 1 or 2-stage level switch).
CAUTION!
Place the system in AUTO mode
Cause: In the event of an error, the system is not
in
[AUTO mode].
Possible consequence: Not all safety equipment is
in operation.
Measure: Always return the system to
[AUTO mode], so that all safety equipment is
active. Pressing the
[Start/Stop] key resets all
existing errors. The system is once more in
[AUTO mode].
In the event of an error, the circulation is switched to
[Manual Stop]. The pump can only be restarted in the manual oper‐
ating status
[Mode].
5.6 "Water level control"
The water top-up solenoid valve can be connected
to terminals [P4] or [P6] of the F module. If two F
modules are used for one swimming pool system,
then it is required that the level evaluation unit and
the solenoid valve of the water top-up are con‐
nected to the same F module. [Water flow 1] to dig‐
ital input [K04], [Water flow 2] to digital input [K05].
Application examples for the F module functions
21