Fig. 6: Outdoor swimming pool: hydraulic connection of the swimming pool metering system to the swimming
pool installation
Advantage:
In-line probe housing cannot become dirty
Disadvantage: Measured values with depletion
5.3.1
Metering system
NOTICE!
Maximum permissible operating pressure of in-line
probe housing
Limit the pressure to a maximum of 2 bar (at 30 °C)
directly at the sample water extraction point using a
pressure reducer, otherwise the maximum permissible
operating pressure of the in-line probe housing will be
exceeded.
Do not allow a back pressure of more than 2 bar
(at 30 °C) to build up at the outlet, otherwise the max‐
imum permissible operating pressure of the in-line
probe housing will be exceeded.
1.
With flow sensor: Push the flow sensor into the in-line probe
housing and tighten the reducing nipple and the mounting
clip
2.
Route the sample water feed via a ball valve from the filter
circuit to the in-line probe housing, see figures above
3.
Route the sample water feed via a ball valve from the filtra‐
tion circuit to the in-line probe housing, see figures above
4.
Install a 1/2" straight union on the filtration circuit pipe for
each injection valve
Assembly