Transport and Storage of the System
3.1
Transport and Storage of the System
CAUTION!
Fractures in plastic material may result from incorrect
loading
– Only move the Ultromat
®
system when empty
– The reservoir wall may not be subjected to point
loads
– Avoid heavy vibrations and impact loads
– Only move the system with suitable hoisting and
lifting equipment
– When using forklift trucks, use long forks, which
extend across the entire depth of the three-
chamber reservoir
– If a crane is used, fit the transport belts such that
shear stress is avoided, even if lifting lugs exist
– The support must be able to carry the weight of the
system
Ambient conditions for storage and transport
Permissible ambient temperature: -5 °C to +50 °C
Humidity: none
Other: No dust, no direct sunlight
Transport and Storage of the System
12