background image

13

 

USER GUIDE // 

PEDIATRIC IMMOBILIZATION SYSTEM PA-190 

Review 2021/09

 

 

 

 

03. 

OPERATION 

 

 

03.1. Transport  

1. Be transferred by common transporting tools: plane, ship or road. 
 
2. The Pediatric immobilization system can be manually handling 
 
3.  The  Pediatric  immobilization  system  should  be  kept  away  from  cutter  or  sharp  objects  in  order  to  avoid 
damage. 
 
4. Nylon bag covered and packed in high-durable carton. 
 
5

. Attachments: certificate, user’s manual. 

 

 

 

 

 

03.2. Storage  

1. Store this Pediatric immobilization system, in the place of damp proof and non-corrosion environment. 
 
2. The Pediatric Immobilization System should be completely dry before being packed. 
 
3. Insert the backboard into the cover, and close the cover flap. 
 
4. Attach the head support and the Pediatric Immobilization System, and fasten the restraints. 
 
5. Slide the Pediatric Immobilization System into its carrying case. 
 

03.3. Maintenance 

1. Inappropriate use and lack of maintenance can cause damage to people and objects. 
 
2.  The  Pediatric  immobilization  system  has  no  moving  parts,  and  therefore  do  not  require  elaborate 
controls.  However,  it  is  recommended  that  you  check  the  surface  of  the  Pediatric  immobilization 
system. 
 
3. If any parts are damaged or broken, we advise rapid replacement by a new one.  
 
4. Always be kept clean (including disinfection): 
 

- Disinfect the Pediatric Immobilization after each use. 

- Remove the head support and the Pediatric Immobilization System. 

- Open the cover flap, and remove the backboard. 

- Wipe all surfaces with disinfectant. 
 

 

Содержание PA-190

Страница 1: ...USER GUIDE PEDIATRIC IMMOBILIZATION SYSTEM PA 190 Review 2021 09...

Страница 2: ......

Страница 3: ...ents of the operators 06 01 8 Intended purpose 06 01 9 General warnings 06 01 10 Specific warnings 09 01 11 Residual risk 09 01 12 Reference standards 10 01 13 Life span 10 02 PRODUCT DESCPRIPTION 10...

Страница 4: ......

Страница 5: ...manufacturer s serial number to identify a specific medical device Indicates the manufacturing date The symbol must be accompanied by a manufacturing Date yyyy mm adjacent to the symbol It is placed t...

Страница 6: ...nts of the operators Promeba s Pediatric immobilization system PA 190 is destined to professional use only The operators must be trained in efficient effective and safe patient transport 01 8 Intended...

Страница 7: ...other than described in this manual is forbidden 10 Do not alter or modify in any way the device any such interference could cause malfunctions and injury to the patient and or rescuer 11 The device m...

Страница 8: ...cluding the regulations relating to technical specifications and or safety requirements and therefore understand the necessary requirements to ensure compliance of the products themselves with all the...

Страница 9: ...ect the product Use a hydroalcoholic based disinfectant and wash with water 5 The device and all its components after washing should be allowed to dry completely before storing 6 Keep clean as routine...

Страница 10: ...d and authorized internal and external technicians In case these annual checks are not carried out the device must be disposed of according to the information in paragraph 01 4 and the manufacturer mu...

Страница 11: ...Open the head support 7 Align the color coded restraints with the patients as follows Restraint Colour coded Area Chest restraint Red Even with patient s armpits Upper hip restraint Yellow Just above...

Страница 12: ...e the patient s chin if needed 13 Wrap the head support around the patient s head The slots in the head support should be in line with the patient s ears 02 3 3 Transport the Patient 1 Use an ambulanc...

Страница 13: ...t the backboard into the cover and close the cover flap 4 Attach the head support and the Pediatric Immobilization System and fasten the restraints 5 Slide the Pediatric Immobilization System into its...

Страница 14: ...E REGISTER The product must be used by trained personnel only having attended specific training for this device and not for similar products Keep this document at least 10 years from the end of life o...

Страница 15: ...as indicated by the manufacturer in this user s manual Keep this document at least 10 years from the end of life of the device DATE TYPE OF SERVICE Maintenance verification extension of useful life OP...

Страница 16: ...t The possession of this document does not entitle no license to these patents The information contained in this document does not affect or change the specifications or product specifications or warr...

Страница 17: ...product or incorrect installation of accessory parts not previously tested iii States or defects of the system in which the product is used or incorporated with the exception of other pro ducts Prome...

Страница 18: ...ta o la inexactitud de la informaci n aqu mencionada All rights reserved Variations can be done without notice Promeba S L is to be considered not responsible for damages caused by the lack or the wro...

Отзывы: