USER’S MANUAL. PROMAX-10
Premium
Page 18
11/2008
j) BER
RESOLUTION
•
LOW
:
BER
measurements every 2s. The minimum measured BER for a
signal at 64QAM and a SR at 6875 Ks/s is 10
-7
•
HIGH
:
BER
measurements every 20 s. The minimum measured BER for a
signal at 64QAM and a SR at 6875 Ks/s is 10
-9
•
CONTINUOUS
:
Continuous measurements up to 30 minutes. The minimum
measured BER for a signal at 64QAM and a SR at 6875 Ks/s is 10
-11
.
The resolution selected in the configuration, applies also in the measurements
done in LOGGER mode, with the exception of the CONT mode that measures time of
20 s (in HIGH mode).
k) SW
The lower line of the screen shows the
version
of the unit
control software
(7.06 in previous figure).
IMPORTANT
To leave the global configuration menu, just press the key of the operating mode
you wish to access.
4.2.2 SCAN operating mode
The
SCAN
operating mode shows, in a single screen, the signal level of all the
active channels in the channel plan by means of a bar-graph. In addition, the exact level
of any particular channel may be measured by simply placing the marker over it (the
measurement is calibrated only for analogue channels; for digital channels refer to the
note at the end of the section).
To access this mode of
operation you should press the
SCAN
[11] key. At first, the field
channel
(C44
in the figure) will appear shaded, indicating that is
selected and modifiable. Next to the channel, it
appears the frequency (655.25 MHz in the figure)
and the level (65 dBµV in the figure) of the channel
where the marker is pointing. The marker is moved
by using the rotary knob [9].
To change the
span
(bandwidth represented on the
screen), first select it by pressing the
rotary knob until you see the "sp" shade (at the
middle bottom of the screen). Then turn the rotary
knob [9]. If you rotate clockwise the span will
increase and if you rotate anti-clockwise it will
decrease.
Span
can acquire the following values:
10, 30, 100, 300 MHz and
full span
.
Figure 8.-
SCAN mode,
full span
.
Figure 9.-
SCAN mode,
span 100 MHz
.
Содержание 10 SE
Страница 1: ...PROMAX 10 Premium ANALIZADOR DE TV CABLE CABLE TV ANALYSER ANALYSEUR DE TV C BLE 0 MI1617...
Страница 2: ......
Страница 4: ......
Страница 5: ...SUMARIO CONTENTS SOMMAIRE Manual espa ol English English manual Fran ais Manuel fran ais...
Страница 6: ......
Страница 16: ...MANUAL DE INSTRUCCIONES PROMAX 10 Premium P gina 8 11 2008...
Страница 56: ...MANUAL DE INSTRUCCIONES PROMAX 10 Premium P gina 48 11 2008...
Страница 58: ...MANUAL DE INSTRUCCIONES PROMAX 10 Premium P gina 50 11 2008...
Страница 106: ...USER S MANUAL PROMAX 10 Premium Page 46 11 2008...
Страница 154: ......