background image

Compliance  with  Local  Building 
Codes  is  the  Responsibility  of  the 
Dealer and the Contractor

     Specifications

Electrical Input:

Voltage                          120 V~
Phase                          1
Frequency                     60 Hz
Power                          150 W

Electrical Output:

Voltage                          13-19 V~
Current                          3.4-5 Amps

     Operating Conditions

Ambient
Temperature 

       +10 C to +40 C

Humidity 

       30% to 75%

Atmospheric
Pressure Range            700 hPa to
 

 

       1060 hPa

     Storage & Shipping 

Ambient
Temperature 

       - 40 C to +70 C

 
Humidity 

       10 to 95 RH

 

 

       (Non-condensing)

Atmospheric
Pressure Range            7 to 15 psi
 

 

       (50 to 106 Kpa)

     Classifications

Classification
of Equipment         Class I

Degree of Protec-
tion against harmful 
ingress of water

Mode of Operation    Intermittent

Ordinary

     Technical Support

For Technical support and repair assis-
tance, contact your local Proma dealer

Check Product Contents

Immediately  upon  receipt,  open  the 
box, examine for damage and com-
pare  contents  to  the  packing  slip.  If 
not  as  ordered,  please  notify  your 
dealer.  If  hidden  shipping  damage 
is identified, immediately contact the 
shipping  service.  Contact  Proma  to 
arrange for replacement goods.

Read all Cautions   /   Warnings on
Labels and in this Manual

Check the product for all caution and 
warning  labels  and  read  them.  Re-
view this manual for all cautions and 
warnings prior to installation.

Check Installation Site and 
Access

Before  installation,  check  room  di-
mensions, locate required tools and 
establish  clear  access  to  the  site. 

SHUT  OFF  ELECTRICAL  POWER

 

to the appropriate outlet.

     Installation Overview

Prepare Electrical Connections

Confirm  the  electrical  connections 
to  be  used.  Locate  all  switches  and 
circuit breakers involved.

Test and Adjust Product after
Installation

It is important to complete any instal-
lation  by  verifying  all  connections 
and controls are functioning properly 
before allowing the device to be used 
for patient treatment.

Train Personnel on Operating
Equipment

Educate staff on the product’s proper 
use, cleaning and disinfection. Identi-
fy parts that may require replacement 
(i.e. lamps, lens covers and fuses).

1. 

2. 

3. 

4. 

5. 

6. 

     Recommended
       Service Tools

•  Allen Wrench Set
•  Bubble Level
•  Tape Measure
•  Phillips Screw Drivers

     Electrical Connections
       and Supply

Note:

  a  licensed  electrician  must  per-

form all wiring. Due to varying city elec-
trical  codes,  the  dealer  should  ensure 
installation will meet local requirements. 
Proma  cannot  be  responsible  for  an 
installation  that  does  not  meet  local 
electrical codes. Installer must meet the 
following additional requirements:

115 Volts AC   (

minimum

)    electrical 

power

Use wiring with insulation rated for 90º 
C  minimum.  Ensure  all  wiring  is  prop-
erly grounded. Protect circuit with circuit 
breaker

CAUTION

Possible  fire  hazard  when  used  with 
oxygen  administering  equipment  other 
than  the  nasal  mask  or  1⁄2  length  bed 
tent  type.  Oxygen  tent  should  not  ex-
tend below mattress support level.

To  ensure  proper  grounding,  plug  unit 
into “Hospital Only” or “Hospital Grade” 
outlet.
Transformer  Cover  to  be  removed  by 
Qualified Service Personnel Only

DANGER!

Risk  of  explosion  if  used  in  the  pres-
ence of flammable anesthetics!
Risk of Fire. Replace fuse as marked

2