Compliance with Local Building
Codes is the Responsibility of the
Dealer and the Contractor
Specifications
Electrical Input:
Voltage 120 V~
Phase 1
Frequency 60 Hz
Power 150 W
Electrical Output:
Voltage 13-19 V~
Current 3.4-5 Amps
Operating Conditions
Ambient
Temperature
+10 C to +40 C
Humidity
30% to 75%
Atmospheric
Pressure Range 700 hPa to
1060 hPa
Storage & Shipping
Ambient
Temperature
- 40 C to +70 C
Humidity
10 to 95 RH
(Non-condensing)
Atmospheric
Pressure Range 7 to 15 psi
(50 to 106 Kpa)
Classifications
Classification
of Equipment Class I
Degree of Protec-
tion against harmful
ingress of water
Mode of Operation Intermittent
Ordinary
Technical Support
For Technical support and repair assis-
tance, contact your local Proma dealer
Check Product Contents
Immediately upon receipt, open the
box, examine for damage and com-
pare contents to the packing slip. If
not as ordered, please notify your
dealer. If hidden shipping damage
is identified, immediately contact the
shipping service. Contact Proma to
arrange for replacement goods.
Read all Cautions / Warnings on
Labels and in this Manual
Check the product for all caution and
warning labels and read them. Re-
view this manual for all cautions and
warnings prior to installation.
Check Installation Site and
Access
Before installation, check room di-
mensions, locate required tools and
establish clear access to the site.
SHUT OFF ELECTRICAL POWER
to the appropriate outlet.
Installation Overview
Prepare Electrical Connections
Confirm the electrical connections
to be used. Locate all switches and
circuit breakers involved.
Test and Adjust Product after
Installation
It is important to complete any instal-
lation by verifying all connections
and controls are functioning properly
before allowing the device to be used
for patient treatment.
Train Personnel on Operating
Equipment
Educate staff on the product’s proper
use, cleaning and disinfection. Identi-
fy parts that may require replacement
(i.e. lamps, lens covers and fuses).
1.
2.
3.
4.
5.
6.
Recommended
Service Tools
• Allen Wrench Set
• Bubble Level
• Tape Measure
• Phillips Screw Drivers
Electrical Connections
and Supply
Note:
a licensed electrician must per-
form all wiring. Due to varying city elec-
trical codes, the dealer should ensure
installation will meet local requirements.
Proma cannot be responsible for an
installation that does not meet local
electrical codes. Installer must meet the
following additional requirements:
115 Volts AC (
minimum
) electrical
power
Use wiring with insulation rated for 90º
C minimum. Ensure all wiring is prop-
erly grounded. Protect circuit with circuit
breaker
CAUTION
Possible fire hazard when used with
oxygen administering equipment other
than the nasal mask or 1⁄2 length bed
tent type. Oxygen tent should not ex-
tend below mattress support level.
To ensure proper grounding, plug unit
into “Hospital Only” or “Hospital Grade”
outlet.
Transformer Cover to be removed by
Qualified Service Personnel Only
DANGER!
Risk of explosion if used in the pres-
ence of flammable anesthetics!
Risk of Fire. Replace fuse as marked
2