B. O-Ring Replacement – each year or as needed
1. Replace the air nozzle’s 3 amber O-rings (part number 8211) if worn or damaged. Replace as needed
and/or each year for preventative maintenance.
2. If there is any fragrance that leaks during the cartridge installation, clean it carefully with a paper towel
and some ethanol or another alcohol.
C. Air Filters and check valve – every 6 months or sooner depending on use
AirQ Scent Shuttle is equipped with two stages of air filtration and a check valve system.
The first stage is a sintered filter (part number 10417). It is can be unscrewed and washed with clean water
as needed. Replace every 6 months.
The second stage filter (part # 5251) collects fine dust. Replace every 6 months or sooner depending on
use. It is accessible behind the air pump panel. A layer of black dust on top of the filtering media is a sign
that the filter should be replaced. To replace it, unscrew the 3 knobs to open the panel and exchange the
filter after pulling off the rubber tubing from both sides of the filter. Note the small triangle showing the
normal air flow direction and position filter accordingly as shown below.
The check valve should be replaced every 6 months (part # 10200). It is also located behind the panel. Note
the position of the check valve. Replace check valve accordingly as shown below.
Reinstall the panel and screw the 3 knobs back in place being careful not to strip the threads. The screws
should align and go in easily.
First Stage
Filter
Second
Stage Filter
Check
Valve
Check
Valve
Second
Stage Filter
Triangle
Pointing
Down
Arrow
Pointing
Down
Arrow
Pointing
Up
6