Prolitec AirQ AQ1200WHTTT-SS Скачать руководство пользователя страница 15

Specifications

IX. Specifications

AirQ Scent Shuttle

Technical Characteristics

 

Reference

AirQ Scent Shuttle : Model AQ1200WHTTT-SS

Type

1 head nebulizer integrated with cartridge

Diameter of particles

300 nm to 1µ micron

Power Input
Input

100 – 240 VAC at 0.6 A

Frequency

50/60 Hz

Protection

Switching power supply

Internal Power

12 VDC at 1.5 A

Back-up battery

Lithium 3V, #CR2032

Performance

Up to 150,000 cu. feet (4,200 cu meters) subject to air flow conditions 

Control

Programmable start & stop times
Programmable output 1 to 50 

Dimensions
Height X Width X Depth

20” x 13.5” x 7”  (50.8 cm X 34.3 cm X 17.8 cm)

Weight with full container 13.5 lb (6.1 kg)
Approvals

UL/CSA listed power supply

Cartridge

Reservoir - 1250ml
Disposable/Recyclable

Patented Prolitec Inc.      

Multiple patents pending

AirQ Scent Shuttle User Guide

© 2015 Prolitec, Inc.

13

Содержание AirQ AQ1200WHTTT-SS

Страница 1: ...User Guide 2015 Prolitec Inc revised Feb 4 2015 Scent Shuttle by Prolitec Model AQ1200WHTTT SS Original Instructions...

Страница 2: ...MAINTENANCE 5 A Changing the Cartridge B O ring Replacement C Air Filter Replacement D Battery Replacement E Fan Replacement V OPERATING INSTRUCTIONS 7 A Unit Programming B Setting Scent Intensity C T...

Страница 3: ...ambient scenting in public spaces such as casinos malls hotels theaters ballrooms convention centers hospitals retirement and assisted living facilities schools and restrooms A single AirQ Scent Shutt...

Страница 4: ...nology Aerosol Spray Can Droplet Diameter m 1 50 Volume per Droplet m3 0 52 65 450 Surface Area per Droplet m2 3 7 854 Relative Volume per Droplet 1 125 000 Relative Weight per Droplet 1 125 000 Numbe...

Страница 5: ...be plugged into an 110VAC or 220VAC power outlet Must be used only with the approved and included power supply The UL and CE compliant power supply converts power to 12V DC to power the appliance If...

Страница 6: ...Inc III Appliance and Controls 4 Appliance and Controls Hose Clamp Hose Connector Air Nozzle First Stage Air Filter Control Display Program Selector Control Buttons Battery Tab Injector Hose DC Power...

Страница 7: ...and hose connector from the cartridge output port located on the top of the cartridge head This is done by unscrewing the hose connector from the cartridge output port and pulling out 5 Remove cartri...

Страница 8: ...ne dust Replace every 6 months or sooner depending on use It is accessible behind the air pump panel A layer of black dust on top of the filtering media is a sign that the filter should be replaced To...

Страница 9: ...ert the new CR2032 battery The positive side of the battery should face your right while looking at the front of the appliance The battery will have a or marking on a side Note The battery is necessar...

Страница 10: ...o select the day You can set maximum of 3 on off programs same for every day or individually for each day After selecting the day press the Set button to advance Now the 1 icon is turned on to indicat...

Страница 11: ...to be treated in Cubic Feet Space to be treated in Cubic Meters Space to be treated in Cubic Feet Space to be treated in Cubic Meters 1 thru 5 1 800 25 000 50 700 1 800 25 000 50 700 6 thru 10 25 000...

Страница 12: ...than recommended in the Settings Table but start from the recommended lowest level and increase progressively for optimum results C The Last Step 1 Set the dial to either Run 24 7 or Run Program if y...

Страница 13: ...nd evaluate detection in 30 minutes Repeat as needed If consumption requires Cartridge change more frequently than each month install an additional appliance The O Rings on the stem that fits into the...

Страница 14: ...and causing an air leak Replace the O Rings by removing the worn one with a pointy tool and rolling on the new ones You detect the fragrance when entering the room but after a while you no longer noti...

Страница 15: ...ternal Power 12 VDC at 1 5 A Back up battery Lithium 3V CR2032 Performance Up to 150 000 cu feet 4 200 cu meters subject to air flow conditions Control Programmable start stop times Programmable outpu...