V. OPERATING INSTRUCTIONS

A.  Unit Programming

1.  Unlock and open the door 

2.  Turn on the power by pressing ON/OFF button in the upper left corner of the control panel.  

3.  Set the Clock

•  Turn the dial to Set Clock. The day-of-week icon will blink.

•  Adjust the day forward or backwards using the +/- buttons on the right side of the control panel.

•  Press the Set button on the lower left corner of the LCD display. The time will blink.

•  Adjust the time forward or backwards using the +/- buttons. AM or PM is indicated on the right side of 

the time digits.  

4.  24/7 Mode

•  If you want the AirQ Scent Shuttle to run continuously -7 days a week, 24 hours a day 7 Days a week 

turn the dial to Run 24/7. If not, skip to Step 5. 

•  You can adjust the fragrance intensity level (1 to 50) using the +/- buttons. Refer to Setting Scent Inten-

sity for the intensity level to set. 

5.  Set multi-program timer

•  Turn the dial to Set Program. The Program icon comes on.

•  The day-of-week icons will all blink, indicating you are selecting all days with the same program. If you 

want to program a specific day, use the +/- buttons to select the day. You can set maximum of 3 on/off 

programs same for every day or individually for each day.  After selecting the day, press the Set button 

to advance.

•  Now the “1” icon is turned on to indicate you are setting program 1. The Rate digits blink to prompt you 

to set the rate. You may set to any value between 1 to 50, or set to 0 to disable the program. Press the 

Set button to advance.

•  If you set the rate to 0, then the current and subsequent programs are all disabled. For example, if the 

rate for program 2 is 0, then program 2 and 3 are disabled.

•  If you set a non-zero rate, then the rate digit changes to “S” to indicate start time. The hour digit should 

blink to prompt you to set the start hour. Use the +/- buttons to set the hour. Then press the Set button 

to advance and set the minute. Press the Set button to advance.

•  The rate digit now changes to “E” to indicate you are setting the end time. Use the +/- buttons to set 

the end time. Press the Set button to advance to the next program.

•  Program icon 2 should now turn on. Use the +/- and Set buttons to set the start and end times for 

program 2 and then for program 3. Note that if you need only 1 or 2 programs for the day, you simply 

disable the subsequent programs by setting its rate to 0.

•  After setting the programs, turn the dial to Run Program.  

8

OPERATING INSTRUCTIONS

Содержание AirQ AQ1200WHTTT-SS

Страница 1: ...User Guide 2015 Prolitec Inc revised Feb 4 2015 Scent Shuttle by Prolitec Model AQ1200WHTTT SS Original Instructions...

Страница 2: ...MAINTENANCE 5 A Changing the Cartridge B O ring Replacement C Air Filter Replacement D Battery Replacement E Fan Replacement V OPERATING INSTRUCTIONS 7 A Unit Programming B Setting Scent Intensity C T...

Страница 3: ...ambient scenting in public spaces such as casinos malls hotels theaters ballrooms convention centers hospitals retirement and assisted living facilities schools and restrooms A single AirQ Scent Shutt...

Страница 4: ...nology Aerosol Spray Can Droplet Diameter m 1 50 Volume per Droplet m3 0 52 65 450 Surface Area per Droplet m2 3 7 854 Relative Volume per Droplet 1 125 000 Relative Weight per Droplet 1 125 000 Numbe...

Страница 5: ...be plugged into an 110VAC or 220VAC power outlet Must be used only with the approved and included power supply The UL and CE compliant power supply converts power to 12V DC to power the appliance If...

Страница 6: ...Inc III Appliance and Controls 4 Appliance and Controls Hose Clamp Hose Connector Air Nozzle First Stage Air Filter Control Display Program Selector Control Buttons Battery Tab Injector Hose DC Power...

Страница 7: ...and hose connector from the cartridge output port located on the top of the cartridge head This is done by unscrewing the hose connector from the cartridge output port and pulling out 5 Remove cartri...

Страница 8: ...ne dust Replace every 6 months or sooner depending on use It is accessible behind the air pump panel A layer of black dust on top of the filtering media is a sign that the filter should be replaced To...

Страница 9: ...ert the new CR2032 battery The positive side of the battery should face your right while looking at the front of the appliance The battery will have a or marking on a side Note The battery is necessar...

Страница 10: ...o select the day You can set maximum of 3 on off programs same for every day or individually for each day After selecting the day press the Set button to advance Now the 1 icon is turned on to indicat...

Страница 11: ...to be treated in Cubic Feet Space to be treated in Cubic Meters Space to be treated in Cubic Feet Space to be treated in Cubic Meters 1 thru 5 1 800 25 000 50 700 1 800 25 000 50 700 6 thru 10 25 000...

Страница 12: ...than recommended in the Settings Table but start from the recommended lowest level and increase progressively for optimum results C The Last Step 1 Set the dial to either Run 24 7 or Run Program if y...

Страница 13: ...nd evaluate detection in 30 minutes Repeat as needed If consumption requires Cartridge change more frequently than each month install an additional appliance The O Rings on the stem that fits into the...

Страница 14: ...and causing an air leak Replace the O Rings by removing the worn one with a pointy tool and rolling on the new ones You detect the fragrance when entering the room but after a while you no longer noti...

Страница 15: ...ternal Power 12 VDC at 1 5 A Back up battery Lithium 3V CR2032 Performance Up to 150 000 cu feet 4 200 cu meters subject to air flow conditions Control Programmable start stop times Programmable outpu...

Страница 16: ...Part No 10556...

Отзывы: